dc.identifier.citation | Lim, J. G. (2022). Behavior of precast CECFST column-to-column connection under compression. Final Year Project (FYP), Nanyang Technological University, Singapore. https://hdl.handle.net/10356/157900 | en_US |
dc.identifier.uri | https://hdl.handle.net/10356/157900 | - |
dc.description.abstract | This paper studies the compressive behaviour of precast concrete-encased concrete-filled steel tubular (CECFST) columns. An experimental programme was conducted on three precast CECFST column-to-column connections and one cast-in-place (CIP) connection under axial and uniaxial eccentric compression. The test results including ultimate failure loads, load-strain curves, and failure modes were presented. It was found that the peak load, maximum moment, and displacement ductility of precast CECFST columns were higher than CIP CECFST columns. A simplified method containing simplified stress distributions and simplified formulas for predicting the cross-section resistance of precast CECFST column-to-column connection was proposed. The test results and the predicted strength were then used to evaluate the applicability of EN 1994-1-1 on the precast connection, and generally, good agreement was achieved. Finally, a general design approach for the precast connection was developed. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Nanyang Technological University | en_US |
dc.relation | ST-16 | en_US |
dc.subject | Engineering::Civil engineering::Construction management | en_US |
dc.title | Behavior of precast CECFST column-to-column connection under compression | en_US |
dc.type | Final Year Project (FYP) | en_US |
dc.contributor.supervisor | Tan Kang Hai | en_US |
dc.contributor.school | School of Civil and Environmental Engineering | en_US |
dc.description.degree | Bachelor of Engineering (Civil) | en_US |
dc.contributor.supervisoremail | CKHTAN@ntu.edu.sg | en_US |
item.grantfulltext | restricted | - |
item.fulltext | With Fulltext | - |
Appears in Collections: | CEE Student Reports (FYP/IA/PA/PI) |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
FYP Final Report.pdf Restricted Access | BEHAVIOR OF PRECAST CECFST COLUMN-TO-COLUMN CONNECTION UNDER COMPRESSION | 2 MB | Adobe PDF | View/Open |
Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.