dc.identifier.citationWu, J. S. Y. (2022). Cable insulation health VI. Final Year Project (FYP), Nanyang Technological University, Singapore. https://hdl.handle.net/10356/158224en_US
dc.identifier.urihttps://hdl.handle.net/10356/158224-
dc.description.abstractIn Singapore, underground cable such as cross-linked polyethylene cable (XLPE) is being used to transmit electrical power from power plant to consumers. The cable's health (durability and effectiveness), which is determined by its insulation, is crucial for maintaining smooth and consistent power supply delivery. The degradation process is a significant problem in cable insulation. Due to various stresses, the cable insulation deteriorates with time. Hence, cable testing (IR test) is required on a regular basis to detect impurities or damage and ensure that the cable is in excellent working condition. Step Voltage Test was used to test the healthiness of cable insulation among various cable tests such as Spot Reading, Time – Resistance Test etc. Polarisation Depolarisation Current (PDC), Polarisation Index (PI) and Dielectric Absorption Ratio (DAR) was then used to further assess cable health. To do so, 3 cable of different aging state, length and brand was tested on. It was found that the 1987 Cable was the healthiest. This project aim to study on using Step Voltage Test to test on the cable’s insulation and find the relationship on how aging affects the insulation health.en_US
dc.language.isoenen_US
dc.publisherNanyang Technological Universityen_US
dc.relationA1017-211en_US
dc.subjectEngineering::Electrical and electronic engineering::Electric poweren_US
dc.titleCable insulation health VIen_US
dc.typeFinal Year Project (FYP)en_US
dc.contributor.supervisorAmer M. Y. M. Ghiasen_US
dc.contributor.schoolSchool of Electrical and Electronic Engineeringen_US
dc.description.degreeBachelor of Engineering (Electrical and Electronic Engineering)en_US
dc.contributor.supervisor2Suo Chang Youen_US
dc.contributor.supervisoremailamer.ghias@ntu.edu.sgen_US
item.grantfulltextrestricted-
item.fulltextWith Fulltext-
Appears in Collections:EEE Student Reports (FYP/IA/PA/PI)
Files in This Item:
File Description SizeFormat 
Final Report Wu Shi Yan Jolene U1922738L.pdf
  Restricted Access
1.91 MBAdobe PDFView/Open

Page view(s)

99
Updated on May 20, 2024

Download(s)

10
Updated on May 20, 2024

Google ScholarTM

Check

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.