Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/159846
Full metadata record
DC FieldValueLanguage
dc.contributor.authorZhong, Yukaien_US
dc.contributor.authorSun, Yaoen_US
dc.contributor.authorTan, Kang Haien_US
dc.contributor.authorZhao, Ouen_US
dc.date.accessioned2022-07-04T07:37:53Z-
dc.date.available2022-07-04T07:37:53Z-
dc.date.issued2021-
dc.identifier.citationZhong, Y., Sun, Y., Tan, K. H. & Zhao, O. (2021). Testing, modelling and design of high strength concrete-filled high strength steel tube (HCFHST) stub columns under combined compression and bending. Engineering Structures, 241, 112334-. https://dx.doi.org/10.1016/j.engstruct.2021.112334en_US
dc.identifier.issn0141-0296en_US
dc.identifier.urihttps://hdl.handle.net/10356/159846-
dc.description.abstractThis paper presents comprehensive experimental and numerical investigations into the structural behaviour and resistances of high strength concrete-filled high strength steel tube (HCFHST) stub columns under combined compression and bending. The combined loading tests were conducted on twelve stub column specimens fabricated from S700 high strength steel square hollow section tubes with two cross-section dimensions and concretes with three grades (C40, C80 and C110). The combined loading test setup, procedures and results, including the failure loads, load–mid-height lateral deflection curves and failure modes, were reported in detail. The failure loads and the evolution of the neutral axis of the HCFHST stub column specimens under combined loading were analysed. The development and distribution of the transverse and longitudinal strains of the outer S700 high strength steel tubes were discussed. The experimental programme was followed by a numerical modelling programme, where finite element models were initially developed and validated against the test results and then used to conduct parametric studies to generate further numerical data. The test and numerical data were used to evaluate the applicability of the relevant design rules, as set out in the European code, American specification and Australian/New Zealand standard, to HCFHST stub columns under combined loading. The evaluation results generally indicated that the European code and Australian/New Zealand standard slightly overestimate the failure loads for HCFHST stub columns under combined loading, while the American specification offers accurate, consistent and safe failure load predictions when applied to eccentrically loaded HCFHST stub columns.en_US
dc.language.isoenen_US
dc.relation04SBS000325C120en_US
dc.relation.ispartofEngineering Structuresen_US
dc.rights© 2021 Elsevier Ltd. All rights reserved.en_US
dc.subjectEngineering::Civil engineeringen_US
dc.titleTesting, modelling and design of high strength concrete-filled high strength steel tube (HCFHST) stub columns under combined compression and bendingen_US
dc.typeJournal Articleen
dc.contributor.schoolSchool of Civil and Environmental Engineeringen_US
dc.identifier.doi10.1016/j.engstruct.2021.112334-
dc.identifier.scopus2-s2.0-85105276014-
dc.identifier.volume241en_US
dc.identifier.spage112334en_US
dc.subject.keywordsCombined Compression and Bendingen_US
dc.subject.keywordsDesign Analysesen_US
dc.description.acknowledgementThe authors thank the financial support from JTC Corporation (Project number: 04SBS000325C120).en_US
item.grantfulltextnone-
item.fulltextNo Fulltext-
Appears in Collections:CEE Journal Articles

SCOPUSTM   
Citations 20

19
Updated on Dec 6, 2023

Web of ScienceTM
Citations 20

16
Updated on Oct 31, 2023

Page view(s)

66
Updated on Nov 30, 2023

Google ScholarTM

Check

Altmetric


Plumx