Please use this identifier to cite or link to this item:
https://hdl.handle.net/10356/160943
Title: | Influence of air on heat transfer of a closed-loop spray cooling system | Authors: | Liu, Pengfei Kandasamy, Ranjith Feng, Huicheng Wong, Teck Neng Toh, Kok Chuan |
Keywords: | Engineering::Mechanical engineering | Issue Date: | 2020 | Source: | Liu, P., Kandasamy, R., Feng, H., Wong, T. N. & Toh, K. C. (2020). Influence of air on heat transfer of a closed-loop spray cooling system. Experimental Thermal and Fluid Science, 111, 109903-. https://dx.doi.org/10.1016/j.expthermflusci.2019.109903 | Project: | NRF2015ENC-GDCR01001-010 | Journal: | Experimental Thermal and Fluid Science | Abstract: | The influence of air must be considered when designing a direct spray cooling system for electronics because of its inevitable existence. In the present study, the influence of air on spray cooling is experimentally investigated with the air volume concentration ranging from 0.06 to 0.65 and the chamber total pressure from 0.44 bar to 1.07 bar. Two dielectric fluids (PF-5060 and FC-3284) are studied due to their compatibility with electronics. The results show that in the current experimental range the spray cooling is mainly affected by the liquid subcooling and surface superheat when air is present. The chamber total pressure appears to have a negligible influence on the spray cooling heat transfer, which differs from the spray cooling behavior without air. This argument holds true from the incidence of nucleate boiling to near the transition boiling regime as long as there is a sufficient amount of air present in the system. The air-entrainment-induced secondary nucleation can possibly leads to the insensitivity of the spray cooling heat transfer to the system pressure. A correlation is developed by incorporating the influence of the spray characteristics, the liquid properties, the chamber pressure, the degree of liquid subcooling, and the surface superheat. It provides a good prediction of the heat transfer rate for air-present spray cooling under current experimental conditions. | URI: | https://hdl.handle.net/10356/160943 | ISSN: | 0894-1777 | DOI: | 10.1016/j.expthermflusci.2019.109903 | Schools: | School of Mechanical and Aerospace Engineering | Rights: | © 2019 Published by Elsevier Inc. All rights reserved. | Fulltext Permission: | none | Fulltext Availability: | No Fulltext |
Appears in Collections: | MAE Journal Articles |
SCOPUSTM
Citations
20
20
Updated on Sep 14, 2023
Web of ScienceTM
Citations
20
15
Updated on Sep 18, 2023
Page view(s)
62
Updated on Sep 21, 2023
Google ScholarTM
Check
Altmetric
Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.