Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/161672
Title: Reliable environmental trace heavy metal analysis with potentiometric ion sensor - reality or a distant dreams
Authors: Lisak, Grzegorz 
Keywords: Engineering::Environmental engineering
Issue Date: 2021
Source: Lisak, G. (2021). Reliable environmental trace heavy metal analysis with potentiometric ion sensor - reality or a distant dreams. Environmental Pollution, 289, 117882-. https://dx.doi.org/10.1016/j.envpol.2021.117882
Journal: Environmental Pollution 
Abstract: Over two decades have passed since polymeric membrane ion-selective electrodes were found to exhibit sufficiently lower detection limits. This in turn brought a great promise to measure trace level concentrations of heavy metals using potentiometric ion sensors at environmental conditions. Despite great efforts, trace analysis of heavy metals using ion-selective electrodes at environmental conditions is still not commercially available. This work will predominantly concentrate on summarizing and evaluating prospects of using potentiometric ion sensors in view of environmental determination of heavy metals in on-site and on-line analysis modes. Challenges associated with development of reliable potentiometric sensors to be operational in environmental conditions will be discussed and reasoning behind unsuccessful efforts to develop potentiometric on-site and on-line environmental ion sensors will be explored. In short, it is now clear that solely lowering the detection limit of the ion-selective electrodes does not guarantee development of successful sensors that would meet the requirement of environmental matrices over long term usage. More pressing challenges of the properties and the performance of the potentiometric sensors must be addressed first before considering extending their sensitivity to low analyte concentrations. These are, in order of importance, selectivity of the ion-selective membrane to main ion followed by the membrane resistance to parallel processes, such as water ingress to the ISM, light sensitivity, change in temperature, presence of gasses in solution and pH and finally resistance of the ion-selective membrane to fouling. In the future, targeted on-site and on-line environmental sensors should be developed, addressing specific environmental conditions. Thus, ion-selective electrodes should be developed with the intention to be suitable to the operational environmental conditions, rather than looking at universal sensor design validated in the idealized and simple sample matrices.
URI: https://hdl.handle.net/10356/161672
ISSN: 0269-7491
DOI: 10.1016/j.envpol.2021.117882
Schools: School of Civil and Environmental Engineering 
Research Centres: Residues and Resource Reclamation Centre 
Nanyang Environment and Water Research Institute 
Rights: © 2021 Elsevier Ltd. All rights reserved.
Fulltext Permission: none
Fulltext Availability: No Fulltext
Appears in Collections:CEE Journal Articles
NEWRI Journal Articles

SCOPUSTM   
Citations 20

27
Updated on Oct 1, 2023

Web of ScienceTM
Citations 20

23
Updated on Sep 28, 2023

Page view(s)

71
Updated on Oct 3, 2023

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.