Please use this identifier to cite or link to this item:
https://hdl.handle.net/10356/161837
Title: | Post-fire behaviour and capacity of high strength concrete-filled high strength steel tube (HCFHST) stub columns under combined compression and bending | Authors: | Zhong, Yukai Jiang, Ke Zhao, Ou |
Keywords: | Engineering::Civil engineering | Issue Date: | 2022 | Source: | Zhong, Y., Jiang, K. & Zhao, O. (2022). Post-fire behaviour and capacity of high strength concrete-filled high strength steel tube (HCFHST) stub columns under combined compression and bending. Engineering Structures, 253, 113837-. https://dx.doi.org/10.1016/j.engstruct.2021.113837 | Project: | RG142/20 | Journal: | Engineering Structures | Abstract: | The post-fire behaviour and capacity of high strength concrete-filled high strength steel tube (HCFHST) stub columns under combined compression and bending have been investigated through testing and numerical modelling and reported in this paper. Eccentric compression tests were conducted on eight square HCFHST stub column specimens after exposure to the ISO-834 standard fire for 15 min, 30 min, 45 min and 80 min and two reference specimens at ambient temperature. The test results, including the load–deformation response at each load stage as well as the confinement effect, the ductility index, the evolution of the neutral axis, the effect of heating duration and the effect of initial loading eccentricity, were discussed. Numerical simulations were then carried out, where thermal and mechanical finite element models were developed and validated against the test results and afterwards used to perform parametric studies to generate further numerical data over a wide range of cross-section dimensions and loading combinations. Given that there are no established design codes for composite structures after exposure to fire, the relevant ambient temperature design rules were evaluated, using post-fire material properties, for their applicability to post-fire HCFHST stub columns under combined compression and bending, based on the test and numerical data. The evaluation results revealed that the European code, American specification and Australian/New Zealand standard result in relatively accurate and consistent post-fire residual resistance predictions. | URI: | https://hdl.handle.net/10356/161837 | ISSN: | 0141-0296 | DOI: | 10.1016/j.engstruct.2021.113837 | Schools: | School of Civil and Environmental Engineering | Rights: | © 2022 Elsevier Ltd. All rights reserved. | Fulltext Permission: | none | Fulltext Availability: | No Fulltext |
Appears in Collections: | CEE Journal Articles |
SCOPUSTM
Citations
50
6
Updated on Dec 4, 2023
Web of ScienceTM
Citations
50
4
Updated on Oct 31, 2023
Page view(s)
80
Updated on Dec 8, 2023
Google ScholarTM
Check
Altmetric
Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.