Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/162381
Title: Field instrumentation for real-time measurement of soil-water characteristic curve
Authors: Hamdany, Abdul Halim
Shen, Yuanjie
Satyanaga, Alfrendo
Rahardjo, Harianto
Lee, Daryl Tsen-Tieng
Nong, Xuefeng
Keywords: Engineering::Civil engineering
Issue Date: 2022
Source: Hamdany, A. H., Shen, Y., Satyanaga, A., Rahardjo, H., Lee, D. T. & Nong, X. (2022). Field instrumentation for real-time measurement of soil-water characteristic curve. International Soil and Water Conservation Research, 10(4), 586-596. https://dx.doi.org/10.1016/j.iswcr.2022.01.007
Journal: International Soil and Water Conservation Research
Abstract: Suction measurement has a vital role in unsaturated soil analysis. However, measuring soil suction remains a challenging task due to a number of issues such as the limited range of suction measurement, cavitation, or long equilibrium time. It is even more challenging when the suction measurement is to be carried on the field. Hence, the development of a new suction measurement device which is able to measure high suction range for a long duration without tedious maintenance and yet portable enough for site measurement is required. In this study, a new sensor which is referred to as NTU Osmotic Tensiometer was developed along with the method to correct for decay and temperature. The NTU osmotic tensiometer is based on polymer swelling capacity in order to measure in-situ soil suction in real time for a very long duration. It requires minimum maintenance as the polymer-based sensor is not affected by the cavitation phenomenon. However, correction for decay and temperature is of paramount importance and therefore explained in this paper. Verification of the NTU osmotic tensiometer was carried out by comparing the field measurement results from the NTU osmotic tensiometer and the small tip tensiometer. The performance of the NTU osmotic tensiometer was found to be comparable with that of the small tip tensiometer, but the NTU osmotic tensiometer is able to measure more than 100 kPa soil suction. Therefore, it is possible to obtain the field soil-water characteristic curve by combining the measured in-situ soil suction from the NTU osmotic tensiometer with the measured in-situ water content from the moisture sensor as illustrated in the paper.
URI: https://hdl.handle.net/10356/162381
ISSN: 2095-6339
DOI: 10.1016/j.iswcr.2022.01.007
Rights: © 2022 International Research and Training Center on Erosion and Sedimentation, China Water and Power Press, and China Institute of Water Resources and Hydropower Research. Publishing services by Elsevier B.V. on behalf of KeAi Communications Co. Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
Fulltext Permission: open
Fulltext Availability: With Fulltext
Appears in Collections:CEE Journal Articles

Files in This Item:
File Description SizeFormat 
1-s2.0-S2095633922000077-main.pdf3.43 MBAdobe PDFView/Open