Title: High-accuracy low-precision machine learning system for health monitoring
Authors: Ang, Wei Jun
Keywords: Engineering::Computer science and engineering
Issue Date: 2022
Publisher: Nanyang Technological University
Source: Ang, W. J. (2022). High-accuracy low-precision machine learning system for health monitoring. Final Year Project (FYP), Nanyang Technological University, Singapore. https://hdl.handle.net/10356/162809
Project: SCSE21-0849
Abstract: Background The increasing rates of cardiovascular diseases (CVDs) within global and local populations is alarming. Although older adults have higher risks of developing CVDs (Rodgers et al., 2019), it is crucial for individuals of all ages to be mindful of their cardiovascular health and take preventive measures or initiate medical care if necessary. This could be done through cardiovascular health monitoring, which allows detection of early symptoms of CVD; a common one being abnormality in heart rate. A wide array of devices for cardiovascular health monitoring purposes have been developed in recent years, ranging from wireless electrocardiogram (ECG) monitors to wearable gadgets such as smartwatches. Given the broad spectrum of heart rates of individuals of different age groups and backgrounds, the accuracy of such devices in detecting heart rate abnormality is a pivotal aspect in the development of these devices. Objective The objective of this project is to develop a high accuracy, low-precision machine learning system to alert users when abnormalities in heart rates for various activities are detected. Methods A Raspberry Pi (RPI) was used as an intermediary for the Himax and smart sensor watch to communicate. Upon booting up the RPI, the smart sensor watch transmits real-time heart rate data from the user to the RPI, which was forwarded to the Himax. Accelerometer data together with the heart rate data was fed into the model for inference. In accordance with the intensity of activity conducted, when an abnormality in heart rate is detected, users will be alerted through a red light on the LED. Results The machine learning system is able to classify correctly with a rate of 99.46% Recommendation Functions such as emergency response and Bluetooth communication between the health sensor band and RPI can be implemented in the future with sufficient time and resources.
URI: https://hdl.handle.net/10356/162809
Schools: School of Computer Science and Engineering 
Fulltext Permission: restricted
Fulltext Availability: With Fulltext
Appears in Collections:SCSE Student Reports (FYP/IA/PA/PI)

Files in This Item:
File Description SizeFormat 
AngWeiJun_FYP_report.pdf
  Restricted Access
1.4 MBAdobe PDFView/Open

Page view(s)

69
Updated on Dec 3, 2023

Download(s)

1
Updated on Dec 3, 2023

Google ScholarTM

Check

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.