Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/164091
Title: High-resolution, non-contact, cellular level imaging of the cornea of the eye in vivo
Authors: Suchand Sandeep, Chandramathi Sukumaran
Chan, Lwin Nyein
Liu, Yu-Chen
Barathi, Veluchamy Amutha
Aung, Tin
Baskaran, Mani
Murukeshan, Vadakke Matham
Keywords: Science::Medicine
Issue Date: 2022
Source: Suchand Sandeep, C. S., Chan, L. N., Liu, Y., Barathi, V. A., Aung, T., Baskaran, M. & Murukeshan, V. M. (2022). High-resolution, non-contact, cellular level imaging of the cornea of the eye in vivo. Optics and Laser Technology, 150, 107922-. https://dx.doi.org/10.1016/j.optlastec.2022.107922
Project: BMRC1619077002
NMRC/STaR/0023/2014
NMRC/TA/0040/2015
NMRC/TA/0057/2017
Journal: Optics and Laser Technology
Abstract: Corneal diseases, along with glaucoma and cataract, are the leading causes of blindness worldwide. While corneal surgery offers good success rates, early diagnosis and disease prevention is the preferred choice over expensive and complex surgical procedures. Non-contact, high-resolution imaging modalities for imaging the corneal structures are highly desirable for clinical examinations for early diagnosis of corneal diseases. The currently used clinical standard is the in vivo confocal laser scanning microscopy, which is a contact based method. In this context, an in-house developed, non-contact, Gaussian epi-illumination based imaging system was used to image corneal injury in preclinical animal models in vivo. New Zealand white rabbits and Wistar rats were used as the preclinical models for the investigations. The lateral resolution of the developed system is 1.1 μm. The images obtained with the developed system, as well as the dimensional information of the corneal structures, are in good agreement with the data previously reported using standard methods. The proposed system offers a simple, easy operable, real-time, non-contact imaging modality for the evaluation of corneal structures in high-resolution.
URI: https://hdl.handle.net/10356/164091
ISSN: 0030-3992
DOI: 10.1016/j.optlastec.2022.107922
Schools: School of Mechanical and Aerospace Engineering 
Research Centres: Centre for Optical and Laser Engineering 
Rights: © 2022 Elsevier Ltd. All rights reserved.
Fulltext Permission: none
Fulltext Availability: No Fulltext
Appears in Collections:MAE Journal Articles

SCOPUSTM   
Citations 50

1
Updated on Feb 18, 2024

Web of ScienceTM
Citations 50

1
Updated on Oct 30, 2023

Page view(s)

94
Updated on Feb 25, 2024

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.