Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/168001
Title: Enhanced immersion two-phase liquid cooling thermal management for data center
Authors: Tong, Marcus Kai Peng
Keywords: Engineering::Mechanical engineering::Fluid mechanics
Issue Date: 2023
Publisher: Nanyang Technological University
Source: Tong, M. K. P. (2023). Enhanced immersion two-phase liquid cooling thermal management for data center. Final Year Project (FYP), Nanyang Technological University, Singapore. https://hdl.handle.net/10356/168001
Project: A037 
Abstract: The Internet of Things, Machine Learning and Artificial Intelligence are driving rapid developments across most industries, requiring data centres and server racks to store and process data. Without proper thermal management, components can fail prematurely, leading to lower reliability and longer downtime. Submerged jet impingement and two-phase cooling have been studied and investigated as a possible means of electronics cooling. The study that will be presented will examine the effects of different jet array configurations with single, three, four and five holes in an array with different total and per-hole volumetric flow rates. The study will assess the impact of change in power settings of the heated impinged surface, the two settings being 14W and 75W. It will also study the effects of using different experimental fluids, both Novec 649 and Deionized Water (DI Water). The results of the study have shown that at 75W, certain configurations will not bring the temperature of the heated plate down. The temperature differences before and after are shown to vary based on the different configurations. The single-hole configuration is shown to have a higher heat transfer coefficient compared to the other configurations for most flow rates. The use of DI water as the experimental fluid was shown to provide larger temperature differences to the heated plate but had a lower Nusselt Number compared to Novec 649. It is recommended that more configurations be set up for future research and an increase in heater power be used in conjunction with Novec 649 as the experimental fluid, to create two-phase cooling.
URI: https://hdl.handle.net/10356/168001
Schools: School of Mechanical and Aerospace Engineering 
Fulltext Permission: restricted
Fulltext Availability: With Fulltext
Appears in Collections:MAE Student Reports (FYP/IA/PA/PI)

Files in This Item:
File Description SizeFormat 
MA4079_Tong_Kai_Peng_Marcus_FYP_Report.pdf
  Restricted Access
5.58 MBAdobe PDFView/Open

Page view(s)

152
Updated on Mar 25, 2025

Download(s)

9
Updated on Mar 25, 2025

Google ScholarTM

Check

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.