dc.identifier.citationJiménez-Arreola, M., Wieland, C. & Romagnoli, A. (2023). Experimental investigation on the dynamics of an Organic Rankine Cycle evaporator with large-mass fins for the purpose of reducing heat input fluctuations. Applied Thermal Engineering, 224, 119995-. https://dx.doi.org/10.1016/j.applthermaleng.2023.119995en_US
dc.identifier.issn1359-4311en_US
dc.identifier.urihttps://hdl.handle.net/10356/169009-
dc.description.abstractWaste heat recovery from energy-intensive processes using Organic Rankine Cycle (ORC) is a promising effective method to reduce large quantities of energy waste and emissions in the planet. However, one of the main technical challenges that remain for its widespread implementation is related to the intermittent and fluctuating nature of the thermal power available from waste heat sources. This paper presents a test rig to study the effect of the geometry of an ORC evaporator to mitigate the adverse effects of thermal power fluctuations of a waste heat source. An experimental campaign is carried out to analyse the dynamic behaviour of the ORC evaporator, which has a custom geometry aimed at increasing its energy storage capacity. The experimental results show that the evaporator is able to dampen fluctuations of the heat source with cycle durations of up to 12 min. It is shown that an evaporator design consisting of a finned tube heat exchanger with large mass of the fins can have a dramatic effect on the thermal inertia of the system. Such a design can help to dampen or reduce some of the variation of the heat source that is transmitted to the ORC system. This, in turn, can allow the ORC system to work in more stable conditions and reduce the need for aggressive control measures or additional heat storage equipment.en_US
dc.language.isoenen_US
dc.relation.ispartofApplied Thermal Engineeringen_US
dc.rights© 2023 Elsevier Ltd. All rights reserved.en_US
dc.subjectEngineering::Mechanical engineeringen_US
dc.titleExperimental investigation on the dynamics of an Organic Rankine Cycle evaporator with large-mass fins for the purpose of reducing heat input fluctuationsen_US
dc.typeJournal Articleen
dc.contributor.schoolSchool of Mechanical and Aerospace Engineeringen_US
dc.contributor.researchEnergy Research Institute @ NTU (ERI@N)en_US
dc.identifier.doi10.1016/j.applthermaleng.2023.119995-
dc.identifier.scopus2-s2.0-85146626167-
dc.identifier.volume224en_US
dc.identifier.spage119995en_US
dc.subject.keywordsWaste Heat Recoveryen_US
dc.subject.keywordsOrganic Rankine Cycleen_US
item.fulltextNo Fulltext-
item.grantfulltextnone-
Appears in Collections:ERI@N Journal Articles
MAE Journal Articles

SCOPUSTM   
Citations 50

1
Updated on Jul 14, 2024

Page view(s)

123
Updated on Jul 18, 2024

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.