Title: Combination of riprap and submerged vane as an abutment scour countermeasure
Authors: Fathi, Abazar
Zomorodian, S. M. Ali
Zolghadr, Masih
Chadee, Aaron
Chiew, Yee-Meng
Kumar, Bimlesh
Martin, Hector
Keywords: Engineering::Civil engineering
Issue Date: 2023
Source: Fathi, A., Zomorodian, S. M. A., Zolghadr, M., Chadee, A., Chiew, Y., Kumar, B. & Martin, H. (2023). Combination of riprap and submerged vane as an abutment scour countermeasure. Fluids, 8(2), 41-. https://dx.doi.org/10.3390/fluids8020041
Journal: Fluids 
Abstract: Scour is one of the main causes of hydraulic structural failures. The present experimental study examines the use of riprap, submerged vanes, and a combination of these for scour reduction around vertical walls and spill-through abutments under clear-water conditions. Specifically, the influence of placing riprap stones with different apron shapes (geometry) and/or a group of submerged vanes of constant height and length on abutment scour was examined. The main aim is to propose the optimum apron geometry and placement of submerged vanes to (1) reduce edge failure at vertical walls and spill-through abutments; and (2) prevent shear failure at the spill-through abutment (no shear failure is observed around the vertical wall abutment). The results show that using ripraps for scour protection is more effective than submerged vanes. However, the highest reduction in scour depth was achieved when a combination of riprap and submerged vanes was used together. This arrangement can reduce the maximum clear-water scour depth by up to 54% and 39% with vertical walls and spill-through abutments, respectively. Furthermore, selecting appropriate apron scale ratios reduces the required riprap volume by up to 46% and 31% for the vertical wall and spill-through abutment, respectively. In addition, the installation of vanes increased the riprap stability and reduced edge failure in both abutments tested. Finally, using riprap aprons with proper scales ratios at the downstream side of the spill-through abutment also prevents shear failure in this zone.
URI: https://hdl.handle.net/10356/169813
ISSN: 2311-5521
DOI: 10.3390/fluids8020041
Schools: School of Civil and Environmental Engineering 
Rights: © 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https:// creativecommons.org/licenses/by/ 4.0/).
Fulltext Permission: open
Fulltext Availability: With Fulltext
Appears in Collections:CEE Journal Articles

Files in This Item:
File Description SizeFormat 
fluids-08-00041.pdf3.75 MBAdobe PDFThumbnail
View/Open

SCOPUSTM   
Citations 50

8
Updated on Mar 15, 2025

Web of ScienceTM
Citations 50

1
Updated on Oct 30, 2023

Page view(s)

136
Updated on Mar 17, 2025

Download(s) 50

45
Updated on Mar 17, 2025

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.