Please use this identifier to cite or link to this item:
https://hdl.handle.net/10356/172011
Title: | Flexible power point tracking aided power ramp rate control for photovoltaic systems with small energy storage capacity | Authors: | Yan, Hein Wai Liang, Gaowen Beniwal, Neha Rodriguez, Ezequiel Farivar, Glen G. Pou, Josep |
Keywords: | Engineering::Electrical and electronic engineering::Electric power::Production, transmission and distribution Engineering::Electrical and electronic engineering::Power electronics |
Issue Date: | 2023 | Source: | Yan, H. W., Liang, G., Beniwal, N., Rodriguez, E., Farivar, G. G. & Pou, J. (2023). Flexible power point tracking aided power ramp rate control for photovoltaic systems with small energy storage capacity. IEEE Transactions On Power Electronics. https://dx.doi.org/10.1109/TPEL.2023.3333534 | Journal: | IEEE Transactions on Power Electronics | Abstract: | Solar photovoltaic (PV) power generation inherently fluctuates due to erratic weather conditions. Although an energy storage system (ESS) can effectively mitigate these fluctuations, conventional methods require a large ESS capacity to control both increasing and decreasing rates of PV power change. This article explores an opportunity to reduce the required ESS capacity in PV power smoothing applications by delegating the power smoothing during positive irradiance transients to a flexible power point tracking algorithm. Therefore, the ESS only needs to regulate the power ramp rate during negative irradiance transients and it no longer requires the reserved capacity for positive transients. After discharging the ESS, the proposed control fully restores it without violating the allowed ramp rate. The efficacy of the proposed power ramp rate control under rapid irradiance transients is demonstrated experimentally using a laboratory-scale setup. Additionally, based on simulated case studies using a specific real-field one-day irradiance profile, the proposed control allows around 64% reduction in the required ESS capacity compared to the conventional ESS-based control. | URI: | https://hdl.handle.net/10356/172011 | ISSN: | 0885-8993 | DOI: | 10.1109/TPEL.2023.3333534 | Schools: | School of Electrical and Electronic Engineering | Research Centres: | Energy Research Institute @ NTU (ERI@N) | Rights: | © 2023 IEEE. All rights reserved. This article may be downloaded for personal use only. Any other use requires prior permission of the copyright holder. The Version of Record is available online at http://doi.org/10.1109/TPEL.2023.3333534. | Fulltext Permission: | open | Fulltext Availability: | With Fulltext |
Appears in Collections: | EEE Journal Articles |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
TPEL_PRRC.pdf | 7.54 MB | Adobe PDF | ![]() View/Open |
SCOPUSTM
Citations
50
9
Updated on Mar 9, 2025
Page view(s)
176
Updated on Mar 26, 2025
Download(s) 20
249
Updated on Mar 26, 2025
Google ScholarTM
Check
Altmetric
Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.