Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/179024
Title: Experimental study of ultra-high-performance fibre-reinforced concrete (UHPFRC)-encased CFST short columns under axial and eccentric compression
Authors: Du, Panwei
Ma, You-Xin
Tan, Kang Hai
Keywords: Earth and Environmental Sciences
Issue Date: 2024
Source: Du, P., Ma, Y. & Tan, K. H. (2024). Experimental study of ultra-high-performance fibre-reinforced concrete (UHPFRC)-encased CFST short columns under axial and eccentric compression. Engineering Structures, 316, 118452-. https://dx.doi.org/10.1016/j.engstruct.2024.118452
Project: L2NICCFP1–2013-4 
Journal: Engineering Structures 
Abstract: This study presents a comprehensive experimental programme and analysis of ultra-high-performance fibre-reinforced concrete (UHPFRC)-encased concrete-filled steel tube (CFST) columns subjected to axial and eccentric compression. Twelve short columns were tested, with six of them utilising UHPFRC encasement while the other six employing normal strength fibre-reinforced concrete (FRC) encasement for comparison purpose. The study focused on the effects of load eccentricity ratio, concrete encasement type, and steel tube configuration. Key findings from the test results including failure modes, load-deflection behaviour, moment-curvature relationships and curvature ductility were examined. The findings showed that UHPFRC-encased CFST columns exhibited significantly enhanced strength and bending capacity, while FRC-encased columns showed remarkable ductility. A notable shift in failure mode was observed with increasing load eccentricity ratio, transitioning from crushing of concrete to compression, and then to balanced failure. Furthermore, applicability of prevalent design codes such as EC4, AIJ, and ACI 318 in calculating the peak loads of UHPFRC- and FRC-encased CFST columns was assessed. The plastic stress distribution methods in EC4 and AIJ overestimated peak loads, while ACI 318's strain compatibility approach accurately predicted FRC-encased columns but not UHPFRC-encased columns. To address this, modifications of the parameters α and β were incorporated into the ACI design method to reflect the relative brittle nature of UHPFRC, resulting in accurate predictions.
URI: https://hdl.handle.net/10356/179024
ISSN: 0141-0296
DOI: 10.1016/j.engstruct.2024.118452
Schools: School of Civil and Environmental Engineering 
Rights: © 2024 Elsevier Ltd. All rights reserved. This article may be downloaded for personal use only. Any other use requires prior permission of the copyright holder. The Version of Record is available online at http://doi.org/10.1016/j.engstruct.2024.118452.
Fulltext Permission: embargo_20261008
Fulltext Availability: With Fulltext
Appears in Collections:CEE Journal Articles

Files in This Item:
File Description SizeFormat 
Experimental study of ultra-high-performance fibre-reinforced concrete (UHPFRC)-encased CFST short columns under axial and eccentric compression.pdf
  Until 2026-10-08
1.42 MBAdobe PDFUnder embargo until Oct 08, 2026

SCOPUSTM   
Citations 50

1
Updated on Mar 16, 2025

Page view(s)

71
Updated on Mar 17, 2025

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.