Please use this identifier to cite or link to this item:
https://hdl.handle.net/10356/179502
Title: | Characterizing the behavior of water interacting with a nano-pore material: a structural investigation in native environment using magnetic resonance approaches | Authors: | Ye, Kai Chin, Sze Yuet Xi, Nicole Lin Sharma, Bhargy Lu, Yunpeng Xue, Kai |
Keywords: | Chemistry | Issue Date: | 2024 | Source: | Ye, K., Chin, S. Y., Xi, N. L., Sharma, B., Lu, Y. & Xue, K. (2024). Characterizing the behavior of water interacting with a nano-pore material: a structural investigation in native environment using magnetic resonance approaches. Chemphyschem, 25(15), e202400053-. https://dx.doi.org/10.1002/cphc.202400053 | Project: | RG82/22 123PGE0003 |
Journal: | Chemphyschem | Abstract: | The study of fluid absorption, particularly that of water, into nanoporous materials has garnered increasing attention in the last decades across a broad range of disciplines. However, most investigation approaches to probe such behaviors are limited by characterization conditions and may lead to misinterpretations. In this study, a combined MRI and MAS NMR method was used to study a nanoporous silica glass to acquire information about its structural framework and interactions with confined water in a native humid environment. Specifically, MRI was used for a quantitative analysis of water extent. While MAS NMR techniques provided structural information of silicate materials, including interactive surface area and framework packing. Analysis of water spin-spin relaxation times (T2) suggested differences in water confinement within the characterized framework. Subsequent unsuccessful delivery of paramagnetic molecule into the pores enabled a quantitative assessment of the dimensions that "bottleneck" the pores. Finally, pore sizes were derived from the paramagnetic molecular size, density function theory (DFT) simulation and characterizations on standard samples. Our result matches with Brunauer-Emmett-Teller (BET) analysis that the pore size is less than 1.3 nm. The use of a paramagnetic probe for pore size determination introduces a new approach of characterization in the liquid phase, offering an alternative to the conventional BET analysis that uses gas molecule as probes. | URI: | https://hdl.handle.net/10356/179502 | ISSN: | 1439-4235 | DOI: | 10.1002/cphc.202400053 | Schools: | School of Materials Science and Engineering School of Chemistry, Chemical Engineering and Biotechnology |
Research Centres: | Center of High Field NMR Spectroscopy and Imaging | Rights: | © 2024 Wiley-VCH GmbH. All rights reserved. | Fulltext Permission: | none | Fulltext Availability: | No Fulltext |
Appears in Collections: | MSE Journal Articles |
SCOPUSTM
Citations
50
1
Updated on May 4, 2025
Page view(s)
96
Updated on May 7, 2025
Google ScholarTM
Check
Altmetric
Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.