Title: A transformerless converter with common-mode decoupling in low-voltage hybrid grids
Authors: Wang, Lei
Zhang, Xinfang
Han, Xiaoqing
Ren, Yu
Zhang, Baifu
Wang, Peng
Keywords: Engineering
Issue Date: 2024
Source: Wang, L., Zhang, X., Han, X., Ren, Y., Zhang, B. & Wang, P. (2024). A transformerless converter with common-mode decoupling in low-voltage hybrid grids. Processes, 12(3), 507-. https://dx.doi.org/10.3390/pr12030507
Journal: Processes 
Abstract: Compared with isolated converters, transformerless converters are a preferred choice in low-voltage grids due to their efficiency and lower cost. However, leakage current and common mode (CM) voltage appear through the converter and ground in hybrid grids, which consist of AC and DC subgrids. The leakage current and CM voltage seriously influence operation and power quality in low-voltage distribution systems. This paper proposes a common-ground-type (CGT) converter equipped with a CM decoupling control strategy to eliminate the leakage current and CM voltage. A CM model is derived, and the leakage current and CM voltage are analyzed in detail. A CGT four-leg converter is constructed to eliminate the high frequency CM voltage. A dual DQ current control loop is developed to suppress the DC double-frequency ripple. Additionally, an active damping method is proposed, based on the neutral current feed-forward plus inductor current feedback, to attenuate the low frequency CM voltage. The proposed converter and control strategy guarantees excellent performance in suppressing leakage current and CM voltage. The DC voltage of the converter connected to the DC grid maintains stability and symmetry. The leakage current is significantly reduced, and the leakage current suppression performance is improved by 83%. The high frequency CM voltage is attenuated from 50%udc to 2%udc, and the low frequency CM voltage is suppressed from approximately 32%udc to 3%udc, which is a significant improvement compared with the traditional method. In addition, the proposed control strategy has good transient performance when the load changes abruptly. Finally, an experimental platform is established to validate the feasibility and performance. The experiment results showed that the proposed control strategy improves the system performance and power quality.
URI: https://hdl.handle.net/10356/179891
ISSN: 2227-9717
DOI: 10.3390/pr12030507
Schools: School of Electrical and Electronic Engineering 
Rights: © 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https:// creativecommons.org/licenses/by/ 4.0/).
Fulltext Permission: open
Fulltext Availability: With Fulltext
Appears in Collections:EEE Journal Articles

Files in This Item:
File Description SizeFormat 
processes-12-00507-v2.pdf22.64 MBAdobe PDFThumbnail
View/Open

SCOPUSTM   
Citations 50

1
Updated on Mar 12, 2025

Page view(s)

54
Updated on Mar 20, 2025

Download(s)

8
Updated on Mar 20, 2025

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.