Please use this identifier to cite or link to this item:
https://hdl.handle.net/10356/180451
Title: | Comparative analysis of vision transformers and conventional convolutional neural networks in detecting referable diabetic retinopathy | Authors: | Goh, Jocelyn Hui Lin Ang, Elroy Srinivasan, Sahana Lei, Xiaofeng Loh, Johnathan Quek, Ten Cheer Xue, Cancan Xu, Xinxing Liu, Yong Cheng, Ching-Yu Rajapakse, Jagath Chandana Tham, Yih-Chung |
Keywords: | Computer and Information Science | Issue Date: | 2024 | Source: | Goh, J. H. L., Ang, E., Srinivasan, S., Lei, X., Loh, J., Quek, T. C., Xue, C., Xu, X., Liu, Y., Cheng, C., Rajapakse, J. C. & Tham, Y. (2024). Comparative analysis of vision transformers and conventional convolutional neural networks in detecting referable diabetic retinopathy. Ophthalmology Science, 4(6), 100552-. https://dx.doi.org/10.1016/j.xops.2024.100552 | Project: | H20c6a0031 | Journal: | Ophthalmology Science | Abstract: | Objective: Vision transformers (ViTs) have shown promising performance in various classification tasks previously dominated by convolutional neural networks (CNNs). However, the performance of ViTs in referable diabetic retinopathy (DR) detection is relatively underexplored. In this study, using retinal photographs, we evaluated the comparative performances of ViTs and CNNs on detection of referable DR. Design: Retrospective study. Participants: A total of 48 269 retinal images from the open-source Kaggle DR detection dataset, the Messidor-1 dataset and the Singapore Epidemiology of Eye Diseases (SEED) study were included. Methods: Using 41 614 retinal photographs from the Kaggle dataset, we developed 5 CNN (Visual Geometry Group 19, ResNet50, InceptionV3, DenseNet201, and EfficientNetV2S) and 4 ViTs models (VAN_small, CrossViT_small, ViT_small, and Hierarchical Vision transformer using Shifted Windows [SWIN]_tiny) for the detection of referable DR. We defined the presence of referable DR as eyes with moderate or worse DR. The comparative performance of all 9 models was evaluated in the Kaggle internal test dataset (with 1045 study eyes), and in 2 external test sets, the SEED study (5455 study eyes) and the Messidor-1 (1200 study eyes). Main Outcome Measures: Area under operating characteristics curve (AUC), specificity, and sensitivity. Results: Among all models, the SWIN transformer displayed the highest AUC of 95.7% on the internal test set, significantly outperforming the CNN models (all P < 0.001). The same observation was confirmed in the external test sets, with the SWIN transformer achieving AUC of 97.3% in SEED and 96.3% in Messidor-1. When specificity level was fixed at 80% for the internal test, the SWIN transformer achieved the highest sensitivity of 94.4%, significantly better than all the CNN models (sensitivity levels ranging between 76.3% and 83.8%; all P < 0.001). This trend was also consistently observed in both external test sets. Conclusions: Our findings demonstrate that ViTs provide superior performance over CNNs in detecting referable DR from retinal photographs. These results point to the potential of utilizing ViT models to improve and optimize retinal photo-based deep learning for referable DR detection. | URI: | https://hdl.handle.net/10356/180451 | ISSN: | 2666-9145 | DOI: | 10.1016/j.xops.2024.100552 | Schools: | School of Computer Science and Engineering | Rights: | © 2024 by the American Academy of Ophthalmology. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). Published by Elsevier Inc. | Fulltext Permission: | open | Fulltext Availability: | With Fulltext |
Appears in Collections: | SCSE Journal Articles |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
1-s2.0-S2666914524000885.pdf | 1.25 MB | Adobe PDF | View/Open |
Page view(s)
64
Updated on Jan 16, 2025
Download(s)
6
Updated on Jan 16, 2025
Google ScholarTM
Check
Altmetric
Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.