Please use this identifier to cite or link to this item:
https://hdl.handle.net/10356/182307
Title: | Single-shot 3D imaging meta-microscope | Authors: | Hao, Huijie Wang, Hao Wang, Xinwei Ding, Xumin Zhang, Shutao Pan, Cheng-Feng Rahman, Md Abdur Ling, Tong Li, Haoyu Tan, Jiubin Yang, Joel K. W. Lu, Wenlong Liu, Jian Hu, Guangwei |
Keywords: | Engineering | Issue Date: | 2024 | Source: | Hao, H., Wang, H., Wang, X., Ding, X., Zhang, S., Pan, C., Rahman, M. A., Ling, T., Li, H., Tan, J., Yang, J. K. W., Lu, W., Liu, J. & Hu, G. (2024). Single-shot 3D imaging meta-microscope. Nano Letters, 24(42), 13364-13373. https://dx.doi.org/10.1021/acs.nanolett.4c03952 | Project: | NAP SUG RG61/23 CRP22-2019-0064 NRF-CRP29-2022-0003 |
Journal: | Nano Letters | Abstract: | Three-dimensional (3D) imaging enables high-precision and high-resolution axial positioning, which is crucial for biological imaging, semiconductor defect monitoring, and other applications. Conventional implementations rely on bulky optical elements or scanning mechanisms, resulting in low speed and complicated setups. Here, we generate the double-helix (DH) point spread function with an all-dielectric metasurface and thus innovate the 3D imaging microscope (hence dubbed meta-microscope), both in 4f and 2f imaging systems. The 4f-meta-microscope with a numerical aperture of 0.7 achieves an axial localization accuracy below 0.12 μm within a 15.47 μm detection range, while the 2f-DH meta-microscope with a numerical aperture of 0.3 shows a 1.12 μm accuracy within a 227.33 μm range. We also demonstrate single-shot and accurate 3D biological imaging of the mouse kidney tissue and peach anther, providing a comprehensive and efficient approach for 3D bioimaging and other applications through a single-shot 3D meta-microscope. | URI: | https://hdl.handle.net/10356/182307 | ISSN: | 1530-6984 | DOI: | 10.1021/acs.nanolett.4c03952 | Schools: | School of Electrical and Electronic Engineering School of Chemistry, Chemical Engineering and Biotechnology |
Organisations: | Institute of Materials Research and Engineering, A*STAR Singapore Eye Research Institute |
Research Centres: | SERI-NTU Advanced Ocular Engineering (STANCE) Program | Rights: | © 2024 American Chemical Society. All rights reserved. | Fulltext Permission: | none | Fulltext Availability: | No Fulltext |
Appears in Collections: | EEE Journal Articles |
SCOPUSTM
Citations
50
2
Updated on Feb 15, 2025
Page view(s)
29
Updated on Feb 16, 2025
Google ScholarTM
Check
Altmetric