Please use this identifier to cite or link to this item:
https://hdl.handle.net/10356/19985
Title: | Centrifugal pump performance subjected to severe off-design operations | Authors: | Zhu, Jing Song. | Keywords: | DRNTU::Engineering::Mechanical engineering::Motors, engines and turbines | Issue Date: | 1997 | Abstract: | Centrifugal pumps are usually designed to operate near the point of best efficiency but many applications require operation over a wide range of capacity. The occurrence of recirculation and prerotation is accepted to be the determining factor in defining the stability and efficiency of partial flow of pump. | URI: | http://hdl.handle.net/10356/19985 | Schools: | School of Mechanical and Production Engineering | Rights: | NANYANG TECHNOLOGICAL UNIVERSITY | Fulltext Permission: | restricted | Fulltext Availability: | With Fulltext |