dc.description.abstractDue to the close correlation between the ethanol concentration in blood and that in saliva, testing saliva samples becomes a good approximation of measuring the test subject’s blood alcohol content. Two combinations of colorimetric reagents were selected to be tested with regards to their detection and ability to show pronounced colour changes as results: potassium dichromate with sulphuric acid; and alcohol oxidase with horseradish peroxidase and 3, 3’, 5, 5’ tetramethylbenzidine. Acidified potassium dichromate was found to have incomplete colorimetric reactions in the liquid phase due to slow reaction rates at low chemical concentrations of ethanol and hence was deemed unsuitable for application in membrane strips even when the concentrations of the reagents have been changed. The enzymatic reaction was able to produce strong colorimetric changes within ten minutes even with low ethanol concentrations of normally found in saliva and various differing amounts of the reagent components were tested to find the best combination which gave the most recognisable colorimetric change. It was found that halving the amount of horseradish peroxidase gave the best distinction as compared to manipulating other reagent amounts. Finally, a limited implantation of the reagent enzymes on cellulose membrane strips was carried out with a focus on investigating the shelf life of the dried enzymes by dissolving them in potassium buffer solutions with 30% sucrose by weight, which produced enzyme-embedded test strips effective for up to one week.en_US
dc.format.extent56 p.en_US
dc.language.isoenen_US
dc.rightsNanyang Technological University-
dc.subjectDRNTU::Engineering::Mechanical engineeringen_US
dc.titleDetection of alcohol content in saliva via chemical and enzymatic methodsen_US
dc.typeFinal Year Project (FYP)en_US
dc.contributor.supervisorLim Chu Singen_US
dc.contributor.schoolSchool of Mechanical and Aerospace Engineeringen_US
dc.description.degreeBachelor of Engineering (Mechanical Engineering)en_US
item.fulltextWith Fulltext-
item.grantfulltextrestricted-
Appears in Collections:MAE Student Reports (FYP/IA/PA/PI)
Files in This Item:
File Description SizeFormat 
M-B210.pdf
  Restricted Access
1.01 MBAdobe PDFView/Open

Page view(s) 50

432
Updated on Jul 11, 2024

Download(s)

3
Updated on Jul 11, 2024

Google ScholarTM

Check

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.