Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/46282
Title: Fouling of nanofiltration and reverse osmosis membranes by organic macromolecules and their mixtures
Authors: Wang, YiNing
Keywords: DRNTU::Engineering::Environmental engineering::Water treatment
Issue Date: 2011
Source: Wang, Y. N. (2011). Fouling of nanofiltration and reverse osmosis membranes by organic macromolecules and their mixtures. Doctoral thesis, Nanyang Technological University, Singapore.
Abstract: The performance of nanofiltration (NF) and reverse osmosis (RO) membranes can be significantly restricted due to fouling by organic macromolecules during water and wastewater treatment. Fouling causes a reduction of the membrane permeation flux, demands more frequent cleaning, and shortens the membrane life span. Proteins are among the main macromolecules that foul NF and RO membranes. Protein fouling (single, binary mixture and protein-polysaccharide mixture) of NF and RO membranes was systematically investigated in the current work. In the study of single protein fouling, the effect of hydrodynamic conditions, feed solution chemistry and membrane properties on fouling by bovine serum albumin (BSA) was evaluated under crossflow conditions over a 4-day fouling period. The initial flux behavior was highly dependent on membrane properties, as membranes with a smoother, more hydrophilic and more charged (favorable electrostatic repulsion with BSA) surface experienced a slower fouling rate. Interestingly, the flux at the end of the 4-day tests (J96hr) showed little dependence on membrane properties, with RO, NF and UF membrane fluxes all converging into a nearly identical value. This suggests that the long-term flux was primarily controlled by the foulant-fouled-membrane surface interaction. Membranes tested at different initial fluxes had a strong tendency to approach a surface-interaction-limited value (limiting flux), although a slightly lower J96hr was observed at higher applied pressures, likely due to foulant layer compaction. BSA fouling was more severe at pH values close to its isoelectric point (IEP), at high ionic strength and in the presence of Ca2+ and Mg2+ as a result of reduced electrostatic repulsion or the promotion of specific ion interactions under these conditions. A linear correlation was observed between J96hr and the square of the zeta potential of BSA, suggesting that this parameter can be potentially a good indicator for predicting the long term fouling behavior.
URI: https://hdl.handle.net/10356/46282
DOI: 10.32657/10356/46282
Fulltext Permission: open
Fulltext Availability: With Fulltext
Appears in Collections:CEE Theses

Files in This Item:
File Description SizeFormat 
Tc0702188H.pdf1.3 MBAdobe PDFThumbnail
View/Open

Page view(s) 20

483
Updated on Jul 25, 2021

Download(s) 10

287
Updated on Jul 25, 2021

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.