Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/46917
Title: A transducer for tomograph imaging applications
Authors: Peng, Jia
Keywords: DRNTU::Engineering::Electrical and electronic engineering
Issue Date: 2006
Source: Peng, J. (2006). A transducer for tomograph imaging applications. Master’s thesis, Nanyang Technological University, Singapore.
Abstract: This project aims at designing a tomography based switched-capacitor capacitance measuring system to detect the presence of individual articles or droplets within the process vessels or pipelines in the form of capacitive-to-voltage conversion. The performance of the front-end interface is crucial to the performance of the measuring system. A new fully-integrated switched-capacitor (SC) front-end capacitive transducer, which employs the correlated double sampling (CDS) technique to reduce the dc offset and 1/f noise of the CMOS amplifier, is proposed.
Description: 140 p.
URI: https://hdl.handle.net/10356/46917
DOI: 10.32657/10356/46917
Rights: Nanyang Technological University
Fulltext Permission: open
Fulltext Availability: With Fulltext
Appears in Collections:EEE Theses

Files in This Item:
File Description SizeFormat 
EEE_THESES_251.pdf12.49 MBAdobe PDFThumbnail