Please use this identifier to cite or link to this item:
https://hdl.handle.net/10356/49741
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Ng, Wei Heng. | |
dc.date.accessioned | 2012-05-23T09:05:12Z | |
dc.date.available | 2012-05-23T09:05:12Z | |
dc.date.copyright | 2012 | en_US |
dc.date.issued | 2012 | |
dc.identifier.uri | http://hdl.handle.net/10356/49741 | |
dc.description.abstract | With the ever rapid advances in silicon chip technology, heat fluxes from high speed electronic devices are increasing at an alarming rate and have now, reached levels where single phase cooling such as air cooled can adequately remove the heat. The use of two-phase cooling in thermosyphons has proven to be the potential alternative in managing high heat loads. A thermosyphon system comprises a condenser, an evaporator base simulating a heat dissipating silicon chip and a coolant chamber. The aim of this project is to investigate the effects of inclination angle and graphite foam geometry modifications on the heat transfer performance of a thermosyphon. A dielectric fluid, namely FC-72, was used and experiments performed . Experimental results showed that inclination have minor effect on the performance of the thermosyphon. However, the trend observed from inclining the thermosyphon showed decreased performance of heat transfer. Next, three different modified graphite foams were prepared and its performance were investigated. All foams performed relatively the same, except at low heat fluxes with cross cut and slant cut foam achieve lower wall temperature as compared to a straight cut and block foam. High speed image capturing of the boiling processes was also carried out to study the differences in bubble dynamics for different inclination angles and geometrical structures. In general, it is evident that bubble nucleation departure diameter and frequency play important roles in heat transfer performance of this two-phase system. | en_US |
dc.format.extent | 104 p. | en_US |
dc.language.iso | en | en_US |
dc.rights | Nanyang Technological University | |
dc.subject | DRNTU::Engineering | en_US |
dc.title | Thermal performance study of a liquid-cooled porous thermosyphon system | en_US |
dc.type | Final Year Project (FYP) | en_US |
dc.contributor.supervisor | Leong Kai Choong | en_US |
dc.contributor.school | School of Mechanical and Aerospace Engineering | en_US |
dc.description.degree | Bachelor of Engineering (Mechanical Engineering) | en_US |
item.fulltext | With Fulltext | - |
item.grantfulltext | restricted | - |
Appears in Collections: | MAE Student Reports (FYP/IA/PA/PI) |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Wei Heng Final Report Revision 3.pdf Restricted Access | 5.54 MB | Adobe PDF | View/Open |
Page view(s)
419
Updated on Apr 17, 2025
Download(s)
10
Updated on Apr 17, 2025
Google ScholarTM
Check
Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.