Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/54262
Title: Energy portal for HVAC applications via smart phones
Authors: Hongamornsin, Supphavit
Keywords: DRNTU::Engineering::Electrical and electronic engineering::Applications of electronics
DRNTU::Engineering::Electrical and electronic engineering::Electronic systems::Signal processing
DRNTU::Engineering::General::Economic and business aspects
Issue Date: 2013
Abstract: Indoor positioning systems (IPS) are seeing more interest and research in recent years. However, such systems require wireless sensor networks to be set up to facilitate the positioning computations of the desired object. New Heating, Ventilation, and Air Conditioning (HVAC) systems are also being developed and improved, now with technology for localized cooling in progress. This project explores the possibility of improving the IPS by ridding the extensive hardware components for the wireless sensor networks required and instead using smart phone devices, desktop computers, and laptop computers to act as a smart sensor. Additionally, the result would then be collected and visualized as a thermal map to provide a tool for an automated localized cooling in the future. The smart phone device would use the Media Access Control addresses and the Received Signal Strength Indicator values from nearby existing wireless routers as parameters for positioning; no wireless sensor networks components are needed. The parameters are then passed through a machine learning technique called Extreme Learning Machines, which would output the position of the device. The result would be displayed on an energy portal web page, which visualizes an approximate thermal profile of the room. HVAC system administrators can then use this result to manually adjust the localized cooling or post the data to the system for automated adjustment. Various alternatives are also explored in the process.
URI: http://hdl.handle.net/10356/54262
Schools: School of Electrical and Electronic Engineering 
Rights: Nanyang Technological University
Fulltext Permission: restricted
Fulltext Availability: With Fulltext
Appears in Collections:EEE Student Reports (FYP/IA/PA/PI)

Files in This Item:
File Description SizeFormat 
EA4134-121.pdf
  Restricted Access
EEE FYP Report, Project Number A4134-1211.91 MBAdobe PDFView/Open

Page view(s)

420
Updated on May 7, 2025

Download(s)

18
Updated on May 7, 2025

Google ScholarTM

Check

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.