dc.contributor.authorYan, KaiGuoen_US
dc.date.accessioned2008-09-17T10:50:58Z
dc.date.accessioned2017-07-23T08:38:39Z
dc.date.available2008-09-17T10:50:58Z
dc.date.available2017-07-23T08:38:39Z
dc.date.copyright2008en_US
dc.date.issued2008
dc.identifier.citationYan, K. G. (2008). Modeling for active needle steering in Percutaneous surgery. Doctoral thesis, Nanyang Technological University, Singapore.
dc.identifier.urihttp://hdl.handle.net/10356/5453
dc.description.abstractPrecise needle insertion is very important for a number of percutaneous interventions. Yet it is very difficult to achieve in practice. Errors caused by the target movement and needle deflection have been observed for a long time. Yet to date, there are few effective physical-based needle steering systems existing for correcting the needle deflection when it occurs. In addition, many procedures are currently not amenable to needles because of obstacles, such as bone or sensitive tissues, which lie between feasible entry points and potential targets. Thus, there is a clear motivation for needle steering in order to provide accurate and dexterous targeting. This work aims to build a needle-tissue interaction model that can be used for designing a needle steering system. A spring-beam-damper model is adopted in this work, which takes into consideration both the elastic, viscoelastic tissue reactions and the needle flexibility, as well as their interaction effects. Unconstrained modal analysis method, which is computationally efficient, is adopted to analyze the system dynamics. Considering the tissue inhomogeneity and computational efficiency, depth-varying mean parameters are proposed in this thesis to calculate the spring and damper effects. Local polynomial approximations in finite depth segments are used to approximate the unknown depth-varying mean parameters. Based on these approaches, an online parameter estimator has been designed using modified least square method with forgetting factor. Extensive experiments have been carried out in various types of phantoms to validate the needle steering model with the online parameter estimator. Results have shown that the model can track the needle tip trajectory with RMSE (Root Mean Square Errors) less than 1mm after convergence even in the presence of large noises, which come from the reduced mode model, poor initial estimation and sensor noises etc. The convergence rate will be greatly improved if the needle gets supported.en_US
dc.rightsNanyang Technological Universityen_US
dc.subjectDRNTU::Engineering::Mechanical engineering::Surgical assistive technology
dc.titleModeling for active needle steering in Percutaneous surgeryen_US
dc.typeThesisen_US
dc.contributor.schoolSchool of Mechanical and Aerospace Engineeringen_US
dc.contributor.supervisorNg Wan Singen_US
dc.description.degreeDOCTOR OF PHILOSOPHY (MAE)en_US
dc.identifier.doihttps://doi.org/10.32657/10356/5453


Files in this item

FilesSizeFormatView
MAE-THESES_1188.pdf2.303Mbapplication/pdfView/Open

This item appears in the following Collection(s)

Show simple item record