Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/61608
Title: Electrochemical biosensors for real-time detection of angiogenesis
Authors: Ng, Shu Rui
Keywords: DRNTU::Engineering::Bioengineering
Issue Date: 2014
Source: Ng, S. R. (2014). Electrochemical biosensors for real-time detection of angiogenesis. Doctoral thesis, Nanyang Technological University, Singapore.
Abstract: Electrochemical biosensors have been made to detect the metabolic markers, pH, O2 and glucose, and nitric oxide (NO), the signalling molecule involved in angiogenesis. A novel three-dimensional (3-D) graphene/ionic liquid (IL) nanocomposite demonstrates highly sensitive detection of NO in phosphate buffered saline (PBS). An arginine-glycine-aspartic acid (RGD) peptide- functionalised biomimetic graphene film has been used as both a cell culture and sensing matrix to detect NO released by human umbilical vein endothelial cells (HUVECs) in real-time under acetylcholine (Ach) stimulation. The amount of NO released is dose-dependent and inhibited by NG-nitro-L-arginine methyl ester (L-NAME). A poly(ethyleneimine) (PEI)-coated anodically electrodeposited iridium oxide film (AEIROF) exhibiting super-Nernstian response to pH functions as miniature pH sensor for detecting acute changes in extracellular pH due to the interaction of porcine aortic ECs (PAECs) with fibronectin and thrombin. Thrombin causes dissolution of fibronectin, extracellular acidification of PAECs and a change in cell morphology from stretched to round cells. O2 and glucose biosensors based on a novel electropolymerised redox polymer are developed and prepared by one-step electropolymerisation of methylene blue (MB+) and pyrrole for the O2 biosensor, with the addition of glucose oxidase (GOD) for the glucose biosensor. The O2 biosensor demonstrates superior sensitivity towards dissolved O2 at atmospheric (atm) O2 concentrations and below and is insensitive to pH. The glucose biosensor exhibits direct electron transfer (DET) and is insensitive to pH from pH 6 to 8 in N2-purged PBS and from pH 4 to 8 in atm O2 PBS.
URI: https://hdl.handle.net/10356/61608
DOI: 10.32657/10356/61608
Schools: School of Chemical and Biomedical Engineering 
Fulltext Permission: open
Fulltext Availability: With Fulltext
Appears in Collections:SCBE Theses

Files in This Item:
File Description SizeFormat 
Ng Shu Rui_ Thesis.pdfThesis18.81 MBAdobe PDFThumbnail
View/Open

Page view(s) 20

749
Updated on May 7, 2025

Download(s) 20

365
Updated on May 7, 2025

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.