Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/65188
Title: Chitosan/PAA based fiber-optic intermodal sensor for nickel cation
Authors: Long, Cassie Huiyi
Keywords: DRNTU::Engineering::Bioengineering
Issue Date: 2015
Abstract: A Fabry–Pérot and an in-fiber Mach-Zehnder fiber interferometer for heavy metal: nickel cation (Ni2+) detection are proposed and experimentally demonstrated. The Fabry–Pérot interferometer fabricated by tapering and micro-hole drilling shows the relationship between reflection signal of the sensor and environmental refractive index is dependent on the size of the micro-hole, such that the closer the micro-hole size is to the core of the sensor the better the sensitivity. In the experiment, a sensor with micro-hole size of 0.5 x7 x9 has obtained a good refractive index sensitivity of -34.55 2.2067nm/RIU. However, due to the poor repeatability the sensor is unable to be employed for the nickel ion detection. Hence, the intermodal Mach-Zehnder interferometer is proposed, the sensor was formed by a sensor length of 4 cm no-core fiber (NCF) sandwiched between two short sections of lead-in/lead-out single-mode fiber (SMF) i.e., SMF-NCF-SMF. A distinct interference pattern is obtained due to the fiber-core mismatch and core-cladding modes interference. The selected interference dip is extremely sensitive to the external refractive indexes, providing a stable refractive index response with sensitivity up to 550.90 nm/RIU. To facilitate the Ni2+ sensing, the NCF based Mach-Zehnder interferometer sensor was functionalized with chitosan (CS) and polyAcrylic Acid (PAA) multilayer film, denoted as [CS/PAA]n where n is number of bilayer, through electrostatic self-assembly. The self-assembly film provides ample Ni2+ adsorption sites which chelate Ni2+ forming a complex and densify the film, thus, refractive index of the film is increased resulting a phase shift of the interference spectrum of the sensor. By calibrating the relationship of Ni2+ concentration with wavelength shift of the sensor, the sensor exhibits a high sensitivity of 0.01434nm/µM with good repeatability and stability, proving itself to be an excellent candidate for the nickel ion detection in rivers, lakes or even drinking water.
URI: http://hdl.handle.net/10356/65188
Rights: Nanyang Technological University
Fulltext Permission: restricted
Fulltext Availability: With Fulltext
Appears in Collections:SCBE Student Reports (FYP/IA/PA/PI)

Files in This Item:
File Description SizeFormat 
FYP Report Long Huiyi Cassie U1121919G.pdf
  Restricted Access
4.33 MBAdobe PDFView/Open

Page view(s) 50

158
Updated on Nov 25, 2020

Download(s) 50

13
Updated on Nov 25, 2020

Google ScholarTM

Check

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.