Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/73374
Full metadata record
DC FieldValueLanguage
dc.contributor.authorHong, Yanen_US
dc.date.accessioned2018-03-05T08:43:58Z
dc.date.available2018-03-05T08:43:58Z
dc.date.issued2018-
dc.identifier.citationHong, Y. (2018). EMulti-modal biomedical sensor for personalized diagnosis and treatment. Doctoral thesis, Nanyang Technological University, Singapore.en_US
dc.identifier.urihttp://hdl.handle.net/10356/73374
dc.description.abstractCMOS has been wildly used in biomedical applications for personalized diagnosis and treatment. The biomedical application of CMOS can be divided into two broad categories: invasive and noninvasive treatments. The invasive procedure includes the micro-electrical stimulation and recording systems that involve microelectrode insertion on tissue for neurological and physiological studies and clinical treatments. The noninvasive procedure includes the wearable health systems, where the optical sensing photoplethysmography (PPG) has been of recent interest due to the electrode-free operation for the heart-rate, the variability extraction for heart-rate and blood oxygen level monitoring (SpO2). In the micro-electrical stimulation/recording systems, the electrode-tissue interface impedance plays a significant role to ensure charge balance, maintain stimulus intensity, limit the over-potential of the electrode under the water window, prevent tissue damage, and more. It is therefore crucial to have an equivalent circuit model with precise fitting to the practical behavior of the electrode-electrolyte interface, which confers great benefits in biomedical studies, circuit designs, impedance monitoring, etc. Meanwhile, the electrode-electrolyte interface impedance will change over time after the implantation of the electrodes in clinical applications, possibly due to tissue growth, inflammation, electrode erosion and so on. It is also vital to monitoring the electrode-electrolyte interface impedance characteristics. For the PPG sensor in non-invasive wearable application, a cost-effective approach is the key requirement in all internet of things (IOT) applications. Consequently, a hybrid-π model and parameter extraction method is explored for electrode-electrolyte interface characterization with superbly accurate reactance in high frequency biomedical applications. A training-based compensation scheme is proposed for the non-ideal circuit effects in I/Q impedance measurement architectures, which has been verified through simulation results obtained from Simulink analysis. A current-excited triple-time-voltage oversampling impedance sensing method is provided to deduce different component values by solving triple simultaneous electric equations at different time nodes during current excitation. To reduce the power consumption, a time-domain impedance sensor readout circuit in the absence of analog-to-digital converter (ADC) is developed. This prototype is fabricated in 0.18-µm CMOS technology. It consumes only 9.84 to 73.2 nJ of energy, and requires merely 3 ms per measurement. As for the PPG sensor in non-invasive wearable health systems, having low power consumption is also vital. A PPG sensor is proposed to detect the slope of photodiode current amplitude by converting only the incremental signal of the cardiac cycle. Afterwards, the PPG signal trend is obtained by a time-domain comparator. Lower power consumption and very much enhanced data compression are achieved by the proposed PPG sensor due to the elimination of ADC in the system. The proposed readout circuit consumes only 5.89 µW and occupies about 0.035-mm2 of area.en_US
dc.format.extent133 p.en_US
dc.language.isoenen_US
dc.publisherNanyang Technological Universityen_US
dc.subjectDRNTU::Engineering::Bioengineeringen_US
dc.titleMulti-modal biomedical sensor for personalized diagnosis and treatmenten_US
dc.typeThesis-Doctor of Philosophyen_US
dc.contributor.supervisorGoh Wang Lingen_US
dc.contributor.schoolSchool of Electrical and Electronic Engineeringen_US
dc.description.degreeDoctor of Philosophyen_US
dc.contributor.organizationA*STAR Institute of Microelectronicsen_US
dc.contributor.supervisoremail-en_US
item.grantfulltextrestricted-
item.fulltextWith Fulltext-
Appears in Collections:EEE Theses
Files in This Item:
File Description SizeFormat 
Thesis.pdf
  Restricted Access
3.75 MBAdobe PDFView/Open

Page view(s) 50

315
Updated on Nov 29, 2020

Google ScholarTM

Check

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.