dc.description.abstractGlobal trends in cooling demands grew rapidly during the past decades due to the higher quality of living standards and the increasing needs for the comfort of humans in this modern era. However, the conventional refrigeration system had impacted our environment in several ways, such as the global warming and ozone depletion. Adoption of adsorption cooling system provides a solution to these impacts as it is a more environmentally friendly and it promotes efficient energy usage as compared to the conventional vapour compression refrigeration system. This report investigated experimentally the performances and the working principles of a two-bed adsorption cooling system employing Silica gel and water as adsorbent-adsorbate pairs. Experiments were conducted to calculate the performance of the system in terms of cooling capacity and coefficient of performance (COP). Several key parameters such as the cycle time and the driving heat source temperatures are optimized to determine the highest COP and specific cooling capacity. Based on the results obtained, it can be deduced that the specific cooling power (SCP) and COP are increased with the increase in hot water inlet temperature. Besides, the optimum adsorption/desorption period for a cycle exists between 550 and 650 seconds. From the present set-up, the optimum COP and SCP are found to be 0.2 and 0.07 kW/kg for chilled water temperature of 10 °C. These findings would serve as a reference to others for further development of an adsorption chiller. It is recommended that more adsorbent beds could be added to the system to reduce the fluctuations of the chilled water temperatures.en_US
dc.format.extent104 p.en_US
dc.language.isoenen_US
dc.rightsNanyang Technological University
dc.subjectDRNTU::Engineering::Mechanical engineeringen_US
dc.titleStudy of heat driven adsorption chiller and compare its performance data with other adsorption chillersen_US
dc.typeFinal Year Project (FYP)en_US
dc.contributor.supervisorAnutosh Chakrabortyen_US
dc.contributor.schoolSchool of Mechanical and Aerospace Engineeringen_US
dc.description.degreeBachelor of Engineering (Mechanical Engineering)en_US
item.grantfulltextrestricted-
item.fulltextWith Fulltext-
Appears in Collections:MAE Student Reports (FYP/IA/PA/PI)
Files in This Item:
File Description SizeFormat 
Chua Wei Cong FYP Report (black font).pdf
  Restricted Access
2017/2018 Final Year Project Report B3154.01 MBAdobe PDFView/Open

Page view(s)

253
Updated on Jul 23, 2024

Download(s)

9
Updated on Jul 23, 2024

Google ScholarTM

Check

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.