Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/79327
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKuwata, Mikinorien
dc.date.accessioned2015-10-21T08:08:56Zen
dc.date.accessioned2019-12-06T13:22:39Z-
dc.date.available2015-10-21T08:08:56Zen
dc.date.available2019-12-06T13:22:39Z-
dc.date.copyright2015en
dc.date.issued2015en
dc.identifier.citationKuwata, M. (2015). Particle Classification by the Tandem Differential Mobility Analyzer–Particle Mass Analyzer System. Aerosol Science and Technology, 49(7), 508-520.en
dc.identifier.urihttps://hdl.handle.net/10356/79327-
dc.description.abstractParticle mass analyzers, such as the aerosol particle mass analyzer (APM) and the Couette centrifugal particle mass analyzer (CPMA), are frequently combined with a differential mobility analyzer (DMA) to measure particle mass mp and effective density ρeff distributions of particles with a specific electrical mobility diameter dm. Combinations of these instruments, which are referred to as the DMA–APM or DMA–CPMA system, are also used to quantify the mass-mobility exponent Dm of non-spherical particles as well as to eliminate multiple charged particles. This study investigates the transfer functions of these setups, focusing especially on the DMA–APM system. The transfer function of the DMA–APM system was derived by multiplying the transfer functions of DMA and APM. The APM transfer function can be calculated using either the uniform or parabolic flow models. The uniform flow model provides an analytical function, while the parabolic flow model is more accurate. The resulting DMA–APM transfer functions were plotted on log(mp)-log(dp) space. A theoretical analysis of the DMA–APM transfer function demonstrated that the resolution of the setup is maintained when the rotation speed ω of APM is scanned to measure distribution. In addition, an equation was derived to numerically calculate the minimum values of the APM resolution parameter λc for eliminating multiple charged particles.en
dc.language.isoenen
dc.relation.ispartofseriesAerosol Science and Technologyen
dc.rights© 2015 American Association for Aerosol Research. This is the author created version of a work that has been peer reviewed and accepted for publication in Aerosol Science and Technology, published by Taylor & Francis on behalf of American Association for Aerosol Research. It incorporates referee’s comments but changes resulting from the publishing process, such as copyediting, structural formatting, may not be reflected in this document.  The published version is available at: [http://dx.doi.org/10.1080/02786826.2015.1045058].en
dc.titleParticle Classification by the Tandem Differential Mobility Analyzer–Particle Mass Analyzer Systemen
dc.typeJournal Articleen
dc.contributor.schoolAsian School of the Environmenten
dc.contributor.researchEarth Observatory of Singaporeen
dc.identifier.doi10.1080/02786826.2015.1045058en
dc.description.versionAccepted versionen
item.grantfulltextopen-
item.fulltextWith Fulltext-
Appears in Collections:EOS Journal Articles
Files in This Item:
File Description SizeFormat 
DMA_APM_theory_20150405.pdf464.48 kBAdobe PDFThumbnail
View/Open
DMA_APM_theory_figures_revised_submission.pdf1.35 MBAdobe PDFThumbnail
View/Open
DMA_APM_theory_SI_revise.pdf166.93 kBAdobe PDFThumbnail
View/Open

SCOPUSTM   
Citations 20

15
Updated on Nov 27, 2023

Web of ScienceTM
Citations 20

14
Updated on Oct 25, 2023

Page view(s) 20

696
Updated on Nov 30, 2023

Download(s) 20

267
Updated on Nov 30, 2023

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.