Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/79554
Full metadata record
DC FieldValueLanguage
dc.contributor.authorWang, Jen-Chiehen
dc.contributor.authorZhou, Yufengen
dc.date.accessioned2014-11-04T07:18:44Zen
dc.date.accessioned2019-12-06T13:28:10Z-
dc.date.available2014-11-04T07:18:44Zen
dc.date.available2019-12-06T13:28:10Z-
dc.date.copyright2014en
dc.date.issued2014en
dc.identifier.citationWang, J.-C., & Zhou, Y. (2015). Suppressing bubble shielding effect in shock wave lithotripsy by low intensity pulsed ultrasound. Ultrasonics, 55, 65-74.en
dc.identifier.issn0041-624Xen
dc.identifier.urihttps://hdl.handle.net/10356/79554-
dc.description.abstractExtracorporeal shock wave lithotripsy (ESWL) has been used as an effective modality to fragment kidney calculi. Because of the bubble shielding effect in the pre-focal region, the acoustic energy delivered to the focus is reduced. Low pulse repetition frequency (PRF) will be applied to dissolve these bubbles for better stone comminution efficiency. In this study, low intensity pulsed ultrasound (LIPUS) beam was aligned perpendicular to the axis of a shock wave (SW) lithotripter at its focus. The light transmission was used to evaluate the compressive wave and cavitation induced by SWs without or with a combination of LIPUS for continuous sonication. It is found that bubble shielding effect becomes dominated with the SW exposure and has a greater significant effect on cavitation than compressive wave. Using the combined wave scheme, the improvement began at the 5th pulse and gradually increased. Suppression effect on bubble shielding is independent on the trigger delay, but increases with the acoustic intensity and pulse duration of LIPUS. The peak negative and integral area of light transmission signal, which present the compressive wave and cavitation respectively, using our strategy at PRF of 1 Hz are comparable to those using SW alone at PRF of 0.1 Hz. In addition, high-speed photography confirmed the bubble activities in both free field and close to a stone surface. Bubble motion in response to the acoustic radiation force by LIPUS was found to be the major mechanism of suppressing bubble shielding effect. There is a 2.6-fold increase in stone fragmentation efficiency after 1,000 SWs at PRF of 1 Hz in combination with LIPUS. In summary, combination of SWs and LIPUS is an effective way of suppressing bubble shielding effect and, subsequently, improving cavitation at the focus for a better outcome.en
dc.format.extent36 p.en
dc.language.isoenen
dc.relation.ispartofseriesUltrasonicsen
dc.rights© 2014 Elsevier B.V. This is the author created version of a work that has been peer reviewed and accepted for publication by Ultrasonics, Elsevier B.V. It incorporates referee’s comments but changes resulting from the publishing process, such as copyediting, structural formatting, may not be reflected in this document. The published version is available at: [http://dx.doi.org/10.1016/j.ultras.2014.08.004].en
dc.subjectDRNTU::Engineering::Mechanical engineering::Mechatronicsen
dc.titleSuppressing bubble shielding effect in shock wave lithotripsy by low intensity pulsed ultrasounden
dc.typeJournal Articleen
dc.contributor.schoolSchool of Mechanical and Aerospace Engineeringen
dc.identifier.doi10.1016/j.ultras.2014.08.004en
dc.description.versionAccepted versionen
item.fulltextWith Fulltext-
item.grantfulltextopen-
Appears in Collections:MAE Journal Articles
Files in This Item:
File Description SizeFormat 
Zhou Yufeng MultiWave_v6 clean.pdfMain Article428.34 kBAdobe PDFThumbnail
View/Open
Zhou Yufeng Figures.pdfFigures1.01 MBAdobe PDFThumbnail
View/Open

SCOPUSTM   
Citations 20

7
Updated on Aug 31, 2020

PublonsTM
Citations 50

6
Updated on Nov 24, 2020

Page view(s) 20

410
Updated on Dec 1, 2020

Download(s) 10

350
Updated on Dec 1, 2020

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.