Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/79607
Full metadata record
DC FieldValueLanguage
dc.contributor.authorFridjonsson, E. O.en
dc.contributor.authorYang, X.en
dc.contributor.authorJohns, M. L.en
dc.contributor.authorWang, Rongen
dc.contributor.authorFane, Anthony Gordonen
dc.date.accessioned2013-11-06T08:24:21Zen
dc.date.accessioned2019-12-06T13:29:11Z-
dc.date.available2013-11-06T08:24:21Zen
dc.date.available2019-12-06T13:29:11Z-
dc.date.copyright2013en
dc.date.issued2013en
dc.identifier.citationYang, X., Fridjonsson, E. O., Johns, M. L., Wang, R., & Fane, A. G. (2014). A non-invasive study of flow dynamics in membrane distillation hollow fiber modules using low-field nuclear magnetic resonance imaging (MRI). Journal of Membrane Science, 451, 46-54.en
dc.identifier.issn0376-7388en
dc.identifier.urihttps://hdl.handle.net/10356/79607-
dc.description.abstractLow-field bench-top nuclear magnetic resonance imaging (MRI) has been applied to investigate the hydrodynamics in novel hollow fiber modules with four different configurations of randomly-packed, spacer-knitted, curly and semi-curly fibers, specifically designed for the membrane distillation (MD) process. Imaging, spatially resolved velocity maps and propagators (probability distributions of displacement/velocity) were all acquired in the modules with flow in the shell side. The MRI data were correlated with overall module performance. The results have revealed that the curly configuration exhibited more significant transverse flow and hence enhanced mixing, compared to the randomly packed configuration; this was consistent with an enhanced MD performance in terms of permeation flux. Interestingly, the velocity maps of the spacer-knitted fiber design indicated a significant flow channeling in the center of the module, despite its enhanced MD performance. Fortunately, combined with further investigations on the localized velocity images of this configuration, the acquisition of propagators provided valuable information in revealing the existence of reduced stagnant regions and significant transverse flow at varied operating conditions, which indicated a better overall mixing and hence confirmed its module performance.en
dc.format.extent9 p.en
dc.language.isoenen
dc.relation.ispartofseriesJournal of membrane scienceen
dc.rights© 2013 Elsevier B.V. This is the author created version of a work that has been peer reviewed and accepted for publication by Journal of Membrane Science, Elsevier. It incorporates referee’s comments but changes resulting from the publishing process, such as copyediting, structural formatting, may not be reflected in this document. The published version is available at: [http://dx.doi.org/10.1016/j.memsci.2013.09.015].en
dc.subjectDRNTU::Engineering::Environmental engineering::Water treatmenten
dc.titleA non-invasive study of flow dynamics in membrane distillation hollow fiber modules using low-field nuclear magnetic resonance imaging (MRI)en
dc.typeJournal Articleen
dc.contributor.schoolSchool of Civil and Environmental Engineeringen
dc.contributor.researchSingapore Membrane Technology Centreen
dc.identifier.doi10.1016/j.memsci.2013.09.015en
dc.description.versionAccepted versionen
dc.identifier.rims172135en
item.grantfulltextopen-
item.fulltextWith Fulltext-
Appears in Collections:CEE Journal Articles
Files in This Item:
File Description SizeFormat 
NMR paper (revised submission2)_20130907.pdfMain article198.93 kBAdobe PDFThumbnail
View/Open
NMR paper_FiguresTables (revised Submission).pdfFigures1.32 MBAdobe PDFThumbnail
View/Open

SCOPUSTM   
Citations 50

21
Updated on Sep 1, 2020

PublonsTM
Citations

21
Updated on Nov 20, 2020

Page view(s)

337
Updated on Nov 25, 2020

Download(s)

503
Updated on Nov 25, 2020

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.