Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/79617
Title: Cascaded fiber-optic Fabry-Perot interferometers with Vernier effect for highly sensitive measurement of axial strain and magnetic field
Authors: Zhang, Peng
Tang, Ming
Gao, Feng
Zhu, Benpeng
Fu, Songnian
Ouyang, Jun
Shum, Perry Ping
Liu, Deming
Keywords: DRNTU::Engineering::Electrical and electronic engineering
Issue Date: 2014
Source: Zhang, P., Tang, M., Gao, F., Zhu, B., Fu, S., Ouyang, J., et al. (2014). Cascaded fiber-optic Fabry-Perot interferometers with Vernier effect for highly sensitive measurement of axial strain and magnetic field. Optics express, 22(16), 19581-19588.
Series/Report no.: Optics express
Abstract: We report a highly sensitive fiber-optic sensor based on two cascaded intrinsic fiber Fabry-Perot interferometers (IFFPIs). The cascaded IFFPIs have different free spectral ranges (FSRs) and are formed by a short section of hollow core photonic crystal fiber sandwiched by two single mode fibers. With the superposition of reflective spectrum with different FSRs, the Vernier effect will be generated in the proposed sensor and we found that the strain sensitivity of the proposed sensor can be improved from 1.6 pm/με for a single IFFPI sensor to 47.14 pm/με by employing the Vernier effect. The sensor embed with a metglas ribbon can be also used to measure the magnetic field according to the similar principle. The sensitivity of the magnetic field measurement is achieved to be 71.57 pm/Oe that is significantly larger than the 2.5 pm/Oe for a single IFFPI sensor.
URI: https://hdl.handle.net/10356/79617
http://hdl.handle.net/10220/20664
ISSN: 1094-4087
DOI: 10.1364/OE.22.019581
Rights: © 2014 Optical Society of America. This paper was published in Optics Express and is made available as an electronic reprint (preprint) with permission of Optical Society of America. The paper can be found at the following official DOI: http://dx.doi.org/10.1364/OE.22.019581.  One print or electronic copy may be made for personal use only. Systematic or multiple reproduction, distribution to multiple locations via electronic or other means, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper is prohibited and is subject to penalties under law.
Fulltext Permission: open
Fulltext Availability: With Fulltext
Appears in Collections:EEE Journal Articles

Files in This Item:
File Description SizeFormat 
oe-22-16-19581.pdf1.5 MBAdobe PDFThumbnail
View/Open

SCOPUSTM   
Citations 5

85
Updated on Mar 10, 2021

PublonsTM
Citations 5

76
Updated on Mar 3, 2021

Page view(s) 50

363
Updated on Dec 5, 2021

Download(s) 10

317
Updated on Dec 5, 2021

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.