Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/79787
Title: Fast depth-sensitive fluorescence measurements in turbid media using cone shell configuration
Authors: Ong, Yi Hong
Liu, Quan
Keywords: DRNTU::Science::Medicine::Biomedical engineering
Issue Date: 2013
Source: Ong, Y. H., & Liu, Q. (2013). Fast depth-sensitive fluorescence measurements in turbid media using cone shell configuration. Journal of Biomedical Optics, 18(11), 110503.
Series/Report no.: Journal of biomedical optics
Abstract: Depth-sensitive fluorescence spectroscopy in a two-layered epithelial tissue phantom was demonstrated using a cone shell configuration implemented by an axicon lens and a fiber assembly including five rings of collection fibers. Each collection fiber ring was located at a different radial distance away from the center, for which fluorescence measurements from all rings showed a larger range of sensitivities to the top and bottom layers compared to the previously reported cone shell configuration. Furthermore, multiple fluorescence spectra corresponding to a range of successive targeted depths can be obtained simultaneously, which shortened data acquisition dramatically and eliminated the mechanical moving components required for depth-sensitive optical measurements in the previous setup. This new setup therefore would be preferred in a clinical setting.
URI: https://hdl.handle.net/10356/79787
http://hdl.handle.net/10220/18796
ISSN: 1083-3668
DOI: 10.1117/1.JBO.18.11.110503
Rights: © 2013 Society of Photo-Optical Instrumentation Engineers (SPIE). This paper was published in Journal of Biomedical Optics and is made available as an electronic reprint (preprint) with permission of Society of Photo-Optical Instrumentation Engineers (SPIE). The paper can be found at the following official DOI: [http://dx.doi.org/10.1117/1.JBO.18.11.110503].  One print or electronic copy may be made for personal use only. Systematic or multiple reproduction, distribution to multiple locations via electronic or other means, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper is prohibited and is subject to penalties under law.
Fulltext Permission: open
Fulltext Availability: With Fulltext
Appears in Collections:SCBE Journal Articles

SCOPUSTM   
Citations 20

6
Updated on Mar 5, 2021

PublonsTM
Citations 20

5
Updated on Mar 7, 2021

Page view(s) 20

484
Updated on Apr 12, 2021

Download(s) 10

271
Updated on Apr 12, 2021

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.