Please use this identifier to cite or link to this item:
https://hdl.handle.net/10356/80016
Title: | Air-breathing membraneless laminar flow-based fuel cell with flow-through anode | Authors: | Shaegh, Seyed Ali Mousavi Nguyen, Nam-Trung Chan, Siew Hwa Zhou, Weijiang |
Keywords: | DRNTU::Engineering::Mechanical engineering::Power resources | Issue Date: | 2011 | Source: | Shaegh, S. A. M., Nguyen, N. T., Chan, S. H., & Zhou, W. (2012). Air-breathing membraneless laminar flow-based fuel cell with flow-through anode. International Journal of Hydrogen Energy, 37(4), 3466-3476. | Series/Report no.: | International journal of hydrogen energy | Abstract: | This paper describes a detailed characterization of laminar flow-based fuel cell (LFFC) with air-breathing cathode for performance (fuel utilization and power density). The effect of flow-over and flow-through anode architectures, as well as operating conditions such as different fuel flow rates and concentrations on the performance of LFFCs was investigated. Formic acid with concentrations of 0.5 M and 1 M in a 0.5 M sulfuric acid solution as supporting electrolyte were exploited with varying flow rates of 20, 50, 100 and 200 μl/min. Because of the improved mass transport to catalytic active sites, the flow-through anode showed improved maximum power density and fuel utilization per single pass compared to flow-over planar anode. Running on 200 μl/min of 1 M formic acid, maximum power densities of 26.5 mW/cm2 and 19.4 mW/cm2 were obtained for the cells with flow-through and flow-over anodes, respectively. In addition, chronoamperometry experiment at flow rate of 100 μl/min with fuel concentrations of 0.5 M and 1 M revealed average current densities of 34.2 mA/cm2 and 52.3 mA/cm2 with average fuel utilization of 16.3% and 21.4% respectively for flow-through design. The flow-over design had the corresponding values of 25.1 mA/cm2 and 35.5 mA/cm2 with fuel utilization of 11.1% and 15.7% for the same fuel concentrations and flow rate. | URI: | https://hdl.handle.net/10356/80016 http://hdl.handle.net/10220/7685 |
DOI: | 10.1016/j.ijhydene.2011.11.051 | Rights: | © 2011 Hydrogen Energy Publications, LLC. This is the author created version of a work that has been peer reviewed and accepted for publication in International Journal of Hydrogen Energy, published by Elsevier on behalf of Hydrogen Energy Publications, LLC. It incorporates referee’s comments but changes resulting from the publishing process, such as copyediting, structural formatting, may not be reflected in this document. The published version is available at: [DOI: http://dx.doi.org/10.1016/j.ijhydene.2011.11.051]. | Fulltext Permission: | open | Fulltext Availability: | With Fulltext |
Appears in Collections: | MAE Journal Articles |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Air-breathing Membraneless Fuel Cell.pdf | 1.24 MB | Adobe PDF | ![]() View/Open |
SCOPUSTM
Citations
5
53
Updated on Sep 1, 2020
PublonsTM
Citations
5
49
Updated on Mar 4, 2021
Page view(s) 5
813
Updated on Jun 25, 2022
Download(s) 5
696
Updated on Jun 25, 2022
Google ScholarTM
Check
Altmetric
Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.