Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/80697
Full metadata record
DC FieldValueLanguage
dc.contributor.authorChaudhuri, Tanayaen
dc.contributor.authorSoh, Yeng Chaien
dc.contributor.authorBose, Sumantaen
dc.contributor.authorXie, Lihuaen
dc.contributor.authorLi, Huaen
dc.date.accessioned2017-03-30T08:03:23Zen
dc.date.accessioned2019-12-06T13:54:55Z-
dc.date.available2017-03-30T08:03:23Zen
dc.date.available2019-12-06T13:54:55Z-
dc.date.issued2016en
dc.identifier.citationChaudhuri, T., Soh, Y. C., Bose, S., Xie, L., & Li, H. (2016). On assuming Mean Radiant Temperature equal to air temperature during PMV-based thermal comfort study in air-conditioned buildings. IECON 2016 - 42nd Annual Conference of the IEEE Industrial Electronics Society, 7065-7070.en
dc.identifier.urihttps://hdl.handle.net/10356/80697-
dc.description.abstractMean Radiant Temperature (MRT) is an important factor of Fanger's PMV model, which is the most popular method to study human thermal comfort. However, it has often been a practice to assume MRT equal to air temperature (Ta) during indoor thermal studies. In this paper, we have studied the consequences of this simplistic assumption on the thermal comfort of occupants in air-conditioned buildings. A worldwide database of about 10000 occupants covering 9 climatic zones and 4 seasons has been studied. The effect on comfort indices-Predicted Mean Vote (PMV), Actual Mean Vote (AMV), Thermal Acceptability Vote (TSA) and Thermal Preference Vote (MCI) are presented. It is observed that even a small difference in Ta and MRT can lead to significant error in determination of thermal comfort. A correlation study between AMV and the six Macpherson factors reveals that MRT has the highest positive correlation with the thermal sensation reported by the occupants. Study of TSA and MCI show that the assumption is more likely to affect comfort level determination in the uncomfortable range.en
dc.description.sponsorshipNRF (Natl Research Foundation, S’pore)en
dc.format.extent6 p.en
dc.language.isoenen
dc.rights© 2016 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. The published version is available at: [http://dx.doi.org/10.1109/IECON.2016.7793073].en
dc.subjectmean radiant temperatureen
dc.subjectcomfort level determinationen
dc.titleOn assuming Mean Radiant Temperature equal to air temperature during PMV-based thermal comfort study in air-conditioned buildingsen
dc.typeConference Paperen
dc.contributor.schoolSchool of Electrical and Electronic Engineeringen
dc.contributor.schoolSchool of Mechanical and Aerospace Engineeringen
dc.contributor.conferenceIECON 2016 - 42nd Annual Conference of the IEEE Industrial Electronics Societyen
dc.contributor.researchEnergy Research Institute @NTUen
dc.identifier.doi10.1109/IECON.2016.7793073en
dc.description.versionAccepted versionen
item.grantfulltextopen-
item.fulltextWith Fulltext-
Appears in Collections:EEE Conference Papers
ERI@N Conference Papers
MAE Conference Papers
Files in This Item:
File Description SizeFormat 
IECON2016-MRT paper-published version.pdfMain article2.2 MBAdobe PDFThumbnail
View/Open

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.