Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/80762
Full metadata record
DC FieldValueLanguage
dc.contributor.authorLi, Beibeien
dc.contributor.authorLu, Rongxingen
dc.contributor.authorWang, Weien
dc.contributor.authorChoo, Kim-Kwang Raymonden
dc.date.accessioned2017-03-31T05:23:55Zen
dc.date.accessioned2019-12-06T13:58:23Z-
dc.date.available2017-03-31T05:23:55Zen
dc.date.available2019-12-06T13:58:23Z-
dc.date.issued2016en
dc.identifier.citationLi, B., Lu, R., Wang, W., & Choo, K.-K. R. (2017). Distributed host-based collaborative detection for false data injection attacks in smart grid cyber-physical system. Journal of Parallel and Distributed Computing, 103, 32-41.en
dc.identifier.issn0743-7315en
dc.identifier.urihttps://hdl.handle.net/10356/80762-
dc.description.abstractFalse data injection (FDI) attacks are crucial security threats to smart grid cyber-physical system (CPS), and could result in cataclysmic consequences to the entire power system. However, due to the high dependence on open information networking, countering FDI attacks is challenging in smart grid CPS. Most existing solutions are based on state estimation (SE) at the highly centralized control center; thus, computationally expensive. In addition, these solutions generally do not provide a high level of security assurance, as evidenced by recent work that smart FDI attackers with knowledge of system configurations can easily circumvent conventional SE-based false data detection mechanisms. In this paper, in order to address these challenges, a novel distributed host-based collaborative detection method is proposed. Specifically, in our approach, we use a conjunctive rule based majority voting algorithm to collaboratively detect false measurement data inserted by compromised phasor measurement units (PMUs). In addition, an innovative reputation system with an adaptive reputation updating algorithm is also designed to evaluate the overall running status of PMUs, by which FDI attacks can be distinctly observed. Extensive simulation experiments are conducted with real-time measurement data obtained from the PowerWorld simulator, and the numerical results fully demonstrate the effectiveness of our proposal.en
dc.format.extent32 p.en
dc.language.isoenen
dc.relation.ispartofseriesJournal of Parallel and Distributed Computingen
dc.subjectSmart grid cyber-physical system (CPS)en
dc.subjectFalse data injection attacken
dc.titleDistributed host-based collaborative detection for false data injection attacks in smart grid cyber-physical systemen
dc.typeJournal Articleen
dc.contributor.schoolSchool of Electrical and Electronic Engineeringen
dc.identifier.doi10.1016/j.jpdc.2016.12.012en
dc.description.versionAccepted versionen
item.grantfulltextopen-
item.fulltextWith Fulltext-
Appears in Collections:EEE Journal Articles
Files in This Item:
File Description SizeFormat 
Distributed host-based collaborative detection for false data injection attacks.pdf734.24 kBAdobe PDFThumbnail
View/Open

SCOPUSTM   
Citations 5

50
Updated on Sep 2, 2020

PublonsTM
Citations 5

50
Updated on Mar 4, 2021

Page view(s)

310
Updated on Aug 16, 2022

Download(s) 5

565
Updated on Aug 16, 2022

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.