Please use this identifier to cite or link to this item:
https://hdl.handle.net/10356/80879
Title: | Gypsum scaling and membrane integrity of osmotically driven membranes: The effect of membrane materials and operating conditions | Authors: | Zhang, Minmin Wang, Yi-Ning Järvelä, Eliisa Wei, Jing Kyllönen, Hanna Wang, Rong Tang, Chuyang Y. |
Keywords: | DRNTU::Engineering::Environmental engineering::Water treatment | Issue Date: | 2016 | Source: | Wang, Y.-N., Järvelä, E., Wei, J., Zhang, M., Kyllönen, H., Wang, R., et al. (2015). Gypsum scaling and membrane integrity of osmotically driven membranes: The effect of membrane materials and operating conditions. Desalination, 377, 1-10. | Series/Report no.: | Desalination | Abstract: | The emerging thin film composite (TFC) forward osmosis (FO) and pressure retarded osmosis (PRO) membranes generally have better separation properties compared with their cellulose triacetate (CTA) counterparts. Nevertheless, their scaling performance has been rarely reported. In the current study, the phenomenon of membrane integrity loss as a result of scaling is reported for the first time for osmotically driven membrane processes (ODMPs). The results show that the TFC membrane suffered marked flux reduction during the scaling in the active-layer-facing-feed-solution (AL-FS) orientation, accompanied with the severe damage of the membrane active layer. The membrane integrity loss is attributed to the scale formation and growth in the confined space between the membrane and the feed spacer. Compared with the CTA membrane, the TFC was more prone to scaling and membrane damage due to its unfavorable physiochemical properties (presence of Ca2+ binding sites and ridge-and-valley roughness). Although antiscalant addition was shown to be effective for scaling control in AL-FS, it was ineffective in the active-layer-facing-draw-solution orientation. The current study reveals the critical need for scaling control in ODMP processes with respect to the membrane integrity and flux stability. The results also have far-reaching implications for FO and PRO membrane design and process operation. | URI: | https://hdl.handle.net/10356/80879 http://hdl.handle.net/10220/38875 |
ISSN: | 0011-9164 | DOI: | 10.1016/j.desal.2015.08.024 | Schools: | School of Civil and Environmental Engineering | Research Centres: | Singapore Membrane Technology Centre | Rights: | © 2015 Elsevier B.V. This is the author created version of a work that has been peer reviewed and accepted for publication by Desalination, Elsevier B.V. It incorporates referee’s comments but changes resulting from the publishing process, such as copyediting, structural formatting, may not be reflected in this document. The published version is available at: [http://dx.doi.org/10.1016/j.desal.2015.08.024]. | Fulltext Permission: | open | Fulltext Availability: | With Fulltext |
Appears in Collections: | CEE Journal Articles |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
MS_FO scaling_20150806_TO NTU.pdf | Main article | 180.71 kB | Adobe PDF | ![]() View/Open |
Figures 20150806_TO NTU.pdf | Figures | 1.19 MB | Adobe PDF | ![]() View/Open |
Tables 20150427_TO NTU.pdf | Tables | 38.86 kB | Adobe PDF | ![]() View/Open |
SCOPUSTM
Citations
10
52
Updated on Sep 17, 2023
Web of ScienceTM
Citations
10
49
Updated on Oct 1, 2023
Page view(s) 50
433
Updated on Oct 2, 2023
Download(s) 10
352
Updated on Oct 2, 2023
Google ScholarTM
Check
Altmetric
Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.