Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/82178
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKalva, Sandeep Kumaren
dc.contributor.authorPramanik, Manojiten
dc.date.accessioned2016-08-23T02:52:19Zen
dc.date.accessioned2019-12-06T14:48:04Z-
dc.date.available2016-08-23T02:52:19Zen
dc.date.available2019-12-06T14:48:04Z-
dc.date.copyright2016en
dc.date.issued2016en
dc.identifier.citationKalva, S. K., & Pramanik, M. (2016). Experimental validation of tangential resolution improvement in photoacoustic tomography using modified delay-and-sum reconstruction algorithm. Journal of Biomedical Optics, 21(8), 086011-.en
dc.identifier.issn1083-3668en
dc.identifier.urihttps://hdl.handle.net/10356/82178-
dc.description.abstractFor a circular scanning geometry in photoacoustic tomography, the axial/radial resolution is spatially invariant and is not affected by the ultrasound transducer (UST, detector) aperture. However, the tangential resolution is dependent on the detector aperture size and it varies spatially. Many techniques were proposed to improve the tangential resolution, such as attaching a concave lens in front of the nonfocused transducer or using a virtual point detector. Both of these methods have difficulties. Therefore, a modified delay-and-sum reconstruction algorithm has been proposed which can be used together with a standard ultrasound detector (nonfocused) to improve the tangential resolution. In this work, we validate the modified delay-and-sum algorithm experimentally for both flat and cylindrically focused USTs. More than threefold improvement in tangential resolution is observed. It is also shown that the object shape is recovered with this modified algorithm, which is very helpful for diagnosis and treatment purposes.en
dc.description.sponsorshipMOE (Min. of Education, S’pore)en
dc.format.extent8 p.en
dc.language.isoenen
dc.relation.ispartofseriesJournal of Biomedical Opticsen
dc.rights© 2016 Society of Photo-optical Instrumentation Engineers (SPIE). This paper was published in Journal of Biomedical Optics and is made available as an electronic reprint (preprint) with permission of SPIE. The published version is available at: [http://dx.doi.org/10.1117/1.JBO.21.8.086011]. One print or electronic copy may be made for personal use only. Systematic or multiple reproduction, distribution to multiple locations via electronic or other means, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper is prohibited and is subject to penalties under law.en
dc.subjectImage reconstructionen
dc.subjectTangential resolutionen
dc.titleExperimental validation of tangential resolution improvement in photoacoustic tomography using modified delay-and-sum reconstruction algorithmen
dc.typeJournal Articleen
dc.contributor.schoolSchool of Chemical and Biomedical Engineeringen
dc.identifier.doi10.1117/1.JBO.21.8.086011en
dc.description.versionPublished versionen
dc.identifier.rims195106en
item.grantfulltextopen-
item.fulltextWith Fulltext-
Appears in Collections:SCBE Journal Articles

SCOPUSTM   
Citations 5

65
Updated on Jul 16, 2024

Web of ScienceTM
Citations 5

51
Updated on Oct 25, 2023

Page view(s) 50

482
Updated on Jul 20, 2024

Download(s) 20

245
Updated on Jul 20, 2024

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.