Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/83003
Full metadata record
DC FieldValueLanguage
dc.contributor.authorWarbal, Pankajen
dc.contributor.authorSaha, Ratan K.en
dc.contributor.authorPramanik, Manojiten
dc.date.accessioned2019-02-14T02:26:36Zen
dc.date.accessioned2019-12-06T15:10:02Z-
dc.date.available2019-02-14T02:26:36Zen
dc.date.available2019-12-06T15:10:02Z-
dc.date.copyright2019en
dc.date.issued2019en
dc.identifier.citationWarbal, P., Pramanik, M., & Saha, R. K. (2019). Impact of sensor apodization on the tangential resolution in photoacoustic tomography. Journal of the Optical Society of America A, 36(2), 245-252. doi:10.1364/JOSAA.36.000245en
dc.identifier.issn1084-7529en
dc.identifier.urihttps://hdl.handle.net/10356/83003-
dc.description.abstractPhotoacoustic tomographic (PAT) image reconstruction with apodized sensors is discussed. A Gaussian function was used to model axisymmetric apodization of sensors and its full width at half maximum (FWHM) was varied to investigate the role of apodization on the PAT image reconstruction. The well known conventional delay-and-sum (CDAS) and recently developed modified delay-and-sum (MDAS) algorithms were implemented to generate reconstructed images. The performance of these algorithms were examined by comparing simulated images formed by these methods and that of ideal point detectors. Simulations in two dimensions were conducted using k-Wave toolbox for three different phantoms. The results produced by the CDAS method are very close to that of ideal point detectors when FWHM of the Gaussian function is small. The MDAS algorithm for flat sensors provides excellent results (comparable to that of point detectors) when FWHM of the Gaussian profile is large. This study elucidates how sensor apodization affects the PAT image reconstruction.en
dc.format.extent20 p.en
dc.language.isoenen
dc.relation.ispartofseriesJournal of the Optical Society of America Aen
dc.rights© 2019 Optical Society of America (OSA). All rights reserved. This paper was published in Journal of the Optical Society of America A and is made available with permission of Optical Society of America (OSA).en
dc.subjectTomographyen
dc.subjectDRNTU::Engineering::Chemical engineeringen
dc.subjectPhotoacoustic Effecten
dc.titleImpact of sensor apodization on the tangential resolution in photoacoustic tomographyen
dc.typeJournal Articleen
dc.contributor.schoolSchool of Chemical and Biomedical Engineeringen
dc.identifier.doi10.1364/JOSAA.36.000245en
dc.description.versionAccepted versionen
dc.identifier.rims209377en
item.fulltextWith Fulltext-
item.grantfulltextopen-
Appears in Collections:SCBE Journal Articles
Files in This Item:
File Description SizeFormat 
revised_version_submitted.pdf655.28 kBAdobe PDFThumbnail
View/Open

SCOPUSTM   
Citations 20

3
Updated on Sep 5, 2020

PublonsTM
Citations

2
Updated on Nov 24, 2020

Page view(s)

150
Updated on Dec 1, 2020

Download(s) 50

52
Updated on Dec 1, 2020

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.