Title: Frequency-domain synthetic aperture focusing for helical ultrasonic imaging
Authors: Jin, H.
Wu, E.
Yang, K.
Chen, Jian
Keywords: Image reconstruction
Ultrasonography
Issue Date: 2017
Source: Jin, H., Chen, J., Wu, E., & Yang, K. (2017). Frequency-domain synthetic aperture focusing for helical ultrasonic imaging. Journal of Applied Physics, 121(13), 134901-.
Series/Report no.: Journal of Applied Physics
Abstract: The synthetic aperture focusing technique (SAFT) is widely used to provide significant improvement in the lateral resolution of ultrasonic images. Frequency-domain SAFT has shown higher accuracy and greater efficiency than time-domain SAFT. However, frequency-domain SAFT should be helix-based for ultrasonic scanning of cylindrical structures such as pipes and axletrees. In this study, a frequency-domain SAFT is proposed for 3D helical ultrasonic imaging applications. This technique adjusts the phase spectra of the images to complete the synthetic aperture focusing process. The focused image is precise because the proposed algorithm is established on the basis of the wave equation in a helical coordinate system. In addition, the algorithm can efficiently separate out point scatterers and present volume scatterers. The experimental results show that the proposed algorithm yields lower side lobes and enhances the angular resolution of the ultrasonic image to approximately 1°– 1.5°, which is much better than the performance of time-domain SAFT. The maximum deviations are only 0.6 mm, 0.5°, and 0.4 mm along the r-axes, θ-axes, and z-axes, respectively, which are appropriate for normal ultrasonic nondestructive testing.
URI: https://hdl.handle.net/10356/83339
http://hdl.handle.net/10220/42575
ISSN: 0021-8979
DOI: 10.1063/1.4979369
Rights: © 2017 American Institute of Physics (AIP). This paper was published in Journal of Applied Physics and is made available as an electronic reprint (preprint) with permission of American Institute of Physics (AIP). The published version is available at: [http://dx.doi.org/10.1063/1.4979369]. One print or electronic copy may be made for personal use only. Systematic or multiple reproduction, distribution to multiple locations via electronic or other means, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper is prohibited and is subject to penalties under law.
Fulltext Permission: open
Fulltext Availability: With Fulltext
Appears in Collections:MAE Journal Articles

Files in This Item:
File Description SizeFormat 
Frequency-domain synthetic aperture focusing for helical ultrasonic imaging.pdf2.03 MBAdobe PDFThumbnail
View/Open

SCOPUSTM   
Citations

3
Updated on Sep 5, 2020

PublonsTM
Citations

4
Updated on Jan 19, 2021

Page view(s)

136
Updated on Jan 20, 2021

Download(s) 50

88
Updated on Jan 20, 2021

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.