Title: | Control of bidirectional DC/DC converter for back to back NPC-based wind turbine system under grid faults | Authors: | Tafti, Hossein Dehghani Roomi, Muhammad M. Tariq, Mohd Khan, Md Shafquat Ullah Maswood, Ali Iftekhar |
Keywords: | Wind Turbine System DC/DC Converter |
Issue Date: | 2016 | Source: | Khan, M. S. U., Maswood, A. I., Tafti, H. D., Roomi, M. M., & Tariq, M. (2016). Control of bidirectional DC/DC converter for back to back NPC-based wind turbine system under grid faults. 2016 4th International Conference on the Development in the in Renewable Energy Technology (ICDRET). | Conference: | 2016 4th International Conference on the Development in the in Renewable Energy Technology (ICDRET) | Abstract: | Viability and reliability of the wind power has made Wind Turbine Systems (WTSs) a popular renewable energy resource. A bidirectional DC/DC converter is proposed in this study for the WTS. The proposed DC/DC converter controls the DC-link voltage by injecting the difference between the extracted power from permanent magnet synchronous generator (PMSG) and the output power of the grid-tied inverter, to the energy storage system. The proposed DC/DC converter controller compensates the shortage of extracted active power from PMSG under wind reduced speed condition in order to inject the constant power to the grid during normal operation. The back to back (BTB) neutral point clamped (NPC) converter is proposed to extract the maximum power from PMSG and inject the extracted power to the grid. The proposed WTS structure achieves fault ride through capability and it can inject reactive power to the grid in order to enhance the PCC voltages under voltage sags. The proportional resonant (PR) current controller is implemented for both rectifier and grid-tied inverter due to its fast response and low steady state error. The adaptive space vector modulation (ASVM) is used to generate the switching signal while balances the DC-link capacitor voltages. The performance of the proposed controller is investigates under grid faults as well as reduced wind speed condition and results have proven the applicability of the proposed controller. | URI: | https://hdl.handle.net/10356/84021 http://hdl.handle.net/10220/41531 |
DOI: | 10.1109/ICDRET.2016.7421483 | Schools: | School of Electrical and Electronic Engineering | Research Centres: | Energy Research Institute @ NTU (ERI@N) | Rights: | © 2016 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. The published version is available at: [http://dx.doi.org/10.1109/ICDRET.2016.7421483]. | Fulltext Permission: | open | Fulltext Availability: | With Fulltext |
Appears in Collections: | EEE Conference Papers |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Control of bidirectional DC DC converter for back to back NPC-based wind turbine system under grid faults.pdf | 1.2 MB | Adobe PDF | ![]() View/Open |
SCOPUSTM
Citations
20
18
Updated on Mar 13, 2025
Page view(s) 10
1,014
Updated on Mar 23, 2025
Download(s) 20
234
Updated on Mar 23, 2025
Google ScholarTM
Check
Altmetric
Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.