dc.identifier.citationLiu, J.-C., & Tan, K. H. (2018). Fire resistance of ultra-high performance strain hardening cementitious composite : residual mechanical properties and spalling resistance. Cement and Concrete Composites, 89, 62-75. doi:10.1016/j.cemconcomp.2018.02.014en
dc.identifier.issn0958-9465en
dc.identifier.urihttps://hdl.handle.net/10356/84190-
dc.identifier.urihttp://hdl.handle.net/10220/50171en
dc.description.abstractUltra high performance strain hardening cementitious composites (UHP-SHCC) is a special type of cement-based composite material with outstanding mechanical and protective performance at room temperature. But its fire performance is unknown and there is a lack of research in this aspect. This study presents an experimental program to study fire resistance of UHP-SHCC under two aspects, viz. high-temperature explosive spalling resistance and residual mechanical performance after a fire. Both compressive strength and tensile strength of UHP-SHCC were found to deteriorate with increasing exposure temperature. Tensile strain-hardening feature of UHP-SHCC would be lost at 200 °C and above. It was found that PE fibers are found not effective in mitigating explosive spalling, although they start to melt at 144 °C. FE-SEM (Field Emission Scanning Electron Microscopy) and EDX (Energy Dispersive X-ray) techniques were used to study the state of fiber, fiber/matrix interaction, and microcracks development. Microscopic study found that melted PE fibers were still present in the cementitious matrix, and the melting did not introduce more microcracks. Furthermore, it was difficult for melted PE fibers to diffuse through the matrix, thus providing the reason that PE fibers did not mitigate explosive spalling in UHP-SHCC.en
dc.description.sponsorshipNRF (Natl Research Foundation, S’pore)en
dc.format.extent37 p.en
dc.language.isoenen
dc.relation.ispartofseriesCement and Concrete Compositesen
dc.rights© 2018 Elsevier Ltd. All rights reserved. This paper was published in Cement and Concrete Composites and is made available with permission of Elsevier Ltd.en
dc.subjectEngineering::Civil engineeringen
dc.subjectStrain Hardeningen
dc.subjectHigh Temperatureen
dc.titleFire resistance of ultra-high performance strain hardening cementitious composite : residual mechanical properties and spalling resistanceen
dc.typeJournal Articleen
dc.contributor.schoolSchool of Civil and Environmental Engineeringen
dc.identifier.doi10.1016/j.cemconcomp.2018.02.014en
dc.description.versionAccepted versionen
item.fulltextWith Fulltext-
item.grantfulltextopen-
Appears in Collections:CEE Journal Articles
Files in This Item:
File Description SizeFormat 
Fire resistance of ultra-high performance strain hardening.pdf2.97 MBAdobe PDFThumbnail
View/Open

Google ScholarTM

Check

Altmetric

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.