Please use this identifier to cite or link to this item:
https://hdl.handle.net/10356/85231
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lang, Michael | en |
dc.contributor.author | Auer, Corinna | en |
dc.contributor.author | Couturier, Karine | en |
dc.contributor.author | Sun, Xiufu | en |
dc.contributor.author | McPhail, Stephen J. | en |
dc.contributor.author | Malkow, Thomas | en |
dc.contributor.author | Fu, Qingxi | en |
dc.contributor.author | Liu, Qinglin | en |
dc.date.accessioned | 2019-05-15T02:09:28Z | en |
dc.date.accessioned | 2019-12-06T15:59:59Z | - |
dc.date.available | 2019-05-15T02:09:28Z | en |
dc.date.available | 2019-12-06T15:59:59Z | - |
dc.date.issued | 2017 | en |
dc.identifier.citation | Lang, M., Auer, C., Couturier, K., Sun, X., McPhail, S. J., Malkow, T., . . . Liu, Q. (2017). Quality assurance of solid oxide fuel cell (SOFC) and electrolyser (SOEC) stacks. ECS Transactions, 78(1), 2077-2086. doi:10.1149/07801.2077ecst | en |
dc.identifier.issn | 1938-5862 | en |
dc.identifier.uri | https://hdl.handle.net/10356/85231 | - |
dc.description.abstract | In the EU-funded project “Solid oxide cell and stack testing and quality assurance” (SOCTESQA) standardized and industry wide test modules and programs for high temperature solid oxide cells and stacks are being developed. These test procedures can be applied for the fuel cell (SOFC), the electrolysis (SOEC) and in the combined SOFC/SOEC mode. In order to optimize the test modules the project partners have tested identical SOC stacks with the same test programs in several testing campaigns. Altogether 10 pre-normative test modules were developed: Start-up, current-voltage characteristics, electrochemical impedance spectroscopy, reactant utilization, reactant gas composition, temperature sensitivity, operation at constant current, operation at varying current, thermal cycling and shut-down. The test modules were validated by comparing the results in terms of repeatability of the different testing campaigns and in terms of reproducibility among the different partners. Moreover, the results are discussed in context to the test input parameters. | en |
dc.format.extent | 10 p. | en |
dc.language.iso | en | en |
dc.relation.ispartofseries | ECS Transactions | en |
dc.rights | © 2017 The Electrochemical Society. All rights reserved. This paper was published in ECS Transactions and is made available with permission of The Electrochemical Society. | en |
dc.subject | Fuel | en |
dc.subject | Stacks | en |
dc.subject | DRNTU::Engineering::Mechanical engineering | en |
dc.title | Quality assurance of solid oxide fuel cell (SOFC) and electrolyser (SOEC) stacks | en |
dc.type | Journal Article | en |
dc.contributor.school | School of Mechanical and Aerospace Engineering | en |
dc.identifier.doi | 10.1149/07801.2077ecst | en |
dc.description.version | Published version | en |
item.fulltext | With Fulltext | - |
item.grantfulltext | open | - |
Appears in Collections: | MAE Journal Articles |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Quality Assurance of Solid Oxide Fuel Cell.pdf | 453.06 kB | Adobe PDF | View/Open |
SCOPUSTM
Citations
50
8
Updated on Mar 28, 2024
Web of ScienceTM
Citations
50
5
Updated on Oct 26, 2023
Page view(s) 20
718
Updated on Mar 28, 2024
Download(s) 20
313
Updated on Mar 28, 2024
Google ScholarTM
Check
Altmetric
Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.