Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/85244
Full metadata record
DC FieldValueLanguage
dc.contributor.authorZhao, Danen
dc.contributor.authorJi, Chenzhenen
dc.contributor.authorWang, Bingen
dc.date.accessioned2019-07-09T02:31:18Zen
dc.date.accessioned2019-12-06T16:00:19Z-
dc.date.available2019-07-09T02:31:18Zen
dc.date.available2019-12-06T16:00:19Z-
dc.date.issued2019en
dc.identifier.citationZhao, D., Ji, C., & Wang, B. (2019). Geometric shapes effect of in-duct perforated orifices on aeroacoustics damping performances at low Helmholtz and Strouhal number. The Journal of the Acoustical Society of America, 145(4), 2126-2137. doi:10.1121/1.5096642en
dc.identifier.issn0001-4966en
dc.identifier.urihttps://hdl.handle.net/10356/85244-
dc.description.abstractIn this work, experimental studies are conducted to measure the aeroacoustics damping performances of 11 in-duct perforated plates in a cold-flow pipe with a variable Mach number. These in-duct plates have the same porosities but different number N and geometric shaped orifices. Here six shapes are considered, i.e., (1) triangle, (2) square, (3) pentagon, (4) hexagon, (5) star, and (6) circle. It is shown that the orifice shape has little influence on power absorption Δ and reflection coefficient R at a lower Helmholtz number He ≤ 0.0903. However, as He is increased, the in-duct plate with a star-shaped orifice is shown to be with much lower Δ in comparison with that of other plates with different shape orifices. In addition, the perforated orifice with the same shape and porosity but a larger N is shown to be associated with 20% more power absorption at approximately He = 0.1244. Δmax is observed to be approximately 85% at about He = 0.0244, as Ma≈0.029. To gain more insights, the quasi-steady model is applied, depending on the Strouhal number Sr. The transition from quasi-steady flow behaviors to unsteady behaviors occurs at approximately Sr = 0.45. The measured minimum reflection coefficient Rmin occurs at Ma ≈ 0.024. This experimental finding is consistent with the quasi-steady prediction.en
dc.description.sponsorshipNRF (Natl Research Foundation, S’pore)en
dc.format.extent12 p.en
dc.language.isoenen
dc.relation.ispartofseriesThe Journal of the Acoustical Society of Americaen
dc.rights© 2019 Acoustical Society of America. All rights reserved. This paper was published in The Journal of the Acoustical Society of America and is made available with permission of Acoustical Society of America.en
dc.subjectAcoustic Transducersen
dc.subjectMaterials Formingen
dc.subjectEngineering::Mechanical engineeringen
dc.titleGeometric shapes effect of in-duct perforated orifices on aeroacoustics damping performances at low Helmholtz and Strouhal numberen
dc.typeJournal Articleen
dc.contributor.schoolSchool of Mechanical and Aerospace Engineeringen
dc.identifier.doi10.1121/1.5096642en
dc.description.versionPublished versionen
item.grantfulltextopen-
item.fulltextWith Fulltext-
Appears in Collections:MAE Journal Articles

SCOPUSTM   
Citations 20

7
Updated on Jul 3, 2022

PublonsTM
Citations 20

6
Updated on Jul 6, 2022

Page view(s)

258
Updated on Aug 7, 2022

Download(s) 50

75
Updated on Aug 7, 2022

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.