Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/85374
Title: Single image reconstruction in active dynamic thermography : a novel approach
Authors: Saxena, Ashish
Raman, Vignesh
Ng, Eddie Yin Kwee
Keywords: Tissue Activity Ratio
Active Dynamic Thermography
Engineering::Mechanical engineering
Issue Date: 2018
Source: Saxena, A., Raman, V., & Ng, E. Y. K. (2018). Single image reconstruction in active dynamic thermography : a novel approach. Infrared Physics & Technology, 9353-58. doi:10.1016/j.infrared.2018.07.020
Series/Report no.: Infrared Physics & Technology
Abstract: In the present study, a novel single thermal image reconstruction method, from the transient image series in active dynamic thermography (ADT), is proposed. ADT is performed with an external stimulation in the form of cooling, over the forearm skin tissue of a human subject, and the resulting transient images (due to thermal recovery) are captured using a non-contact Infrared (IR) thermal camera. A unique tissue activity ratio (), the ratio of thermal recovery rate to excitation rate is calculated at each pixel, and hence, a single thermal image (called image) is reconstructed. Using a conventional single image reconstruction method in ADT called Tau (τ) image method, a comparative study is performed, which reveals that the blood vessel contrast produced by the image is at least 1.3 times higher than the equivalent τ image. Further, using this image, the diameter of the blood vessel is calculated, and the values are compared with the τ image and the earlier reported thermography results on the same subjects, which reveals that the reconstructed image is an equivalent qualitative and quantitative representation of transient sequence images. The method devised can further be implemented for medical ADT procedures.
URI: https://hdl.handle.net/10356/85374
http://hdl.handle.net/10220/49219
ISSN: 1350-4495
DOI: 10.1016/j.infrared.2018.07.020
Schools: School of Mechanical and Aerospace Engineering 
Rights: © 2018 Elsevier. All rights reserved. This paper was published in Infrared Physics & Technology and is made available with permission of Elsevier.
Fulltext Permission: open
Fulltext Availability: With Fulltext
Appears in Collections:MAE Journal Articles

Files in This Item:
File Description SizeFormat 
Single image reconstruction in active dynamic thermography A novel approach.pdf946.57 kBAdobe PDFThumbnail
View/Open

SCOPUSTM   
Citations 50

10
Updated on May 6, 2025

Web of ScienceTM
Citations 20

10
Updated on Oct 24, 2023

Page view(s)

285
Updated on May 5, 2025

Download(s) 50

158
Updated on May 5, 2025

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.