Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/87061
Full metadata record
DC FieldValueLanguage
dc.contributor.authorDehghani Tafti, Hosseinen
dc.contributor.authorCao, Shuyuen
dc.contributor.authorRavi Kishore, Kanamarlapudi Venkataen
dc.contributor.authorFarivar, Ghiasen
dc.contributor.authorYeo, Howe Lien
dc.contributor.authorSriram, Vaisambhayana Brihadeeswaraen
dc.contributor.authorPou, Josepen
dc.contributor.authorTripathi, Anshumanen
dc.date.accessioned2018-01-10T03:20:16Zen
dc.date.accessioned2019-12-06T16:34:17Z-
dc.date.available2018-01-10T03:20:16Zen
dc.date.available2019-12-06T16:34:17Z-
dc.date.issued2017en
dc.identifier.citationDehghani Tafti, H., Cao, S., Ravi Kishore, K. V., Farivar, G., Yeo, H. L., Sriram, V. B., et al. (2017). Control of active front-end rectifier of the solid-state transformer with improved dynamic performance during precharging. 2017 Asian Conference on Energy, Power and Transportation Electrification (ACEPT 2017).en
dc.identifier.urihttps://hdl.handle.net/10356/87061-
dc.description.abstractThe control of the active front-end rectifier of the three-stage solid-state transformer (SST) system is addressed in this paper. A comprehensive precharging sequence is introduced for the active front-end rectifier of the SST to limit the inrush current during the start-up process to its nominal current. The proposed precharging algorithm consists of two phases, passive and active precharging. The precharging resistor limits the current during the passive precharging, while a ramp increase of the voltage reference is used in the controller during the active precharging to prevent large inrush currents. Additionally, a feed-forward voltage compensator is added to the voltage reference of the controller to improve the dynamic response at the beginning of the active precharging. The proposed algorithm is detailed and simulation results on a 4-kW active front-end converter are presented to validate its performance. The simulation results under various operation conditions show the ability of the proposed algorithm to limit the converter current to its nominal value during the precharging as well as to control the dc-link voltage under different load changes.en
dc.format.extent6 p.en
dc.language.isoenen
dc.rights© 2017 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. The published version is available at: [http://dx.doi.org/10.1109/ACEPT.2017.8168622].en
dc.subjectActive Front-end Converteren
dc.subjectGrid-connected Rectifieren
dc.titleControl of active front-end rectifier of the solid-state transformer with improved dynamic performance during prechargingen
dc.typeConference Paperen
dc.contributor.schoolSchool of Electrical and Electronic Engineeringen
dc.contributor.conference2017 Asian Conference on Energy, Power and Transportation Electrification (ACEPT 2017)en
dc.contributor.researchEnergy Research Institute @NTUen
dc.identifier.doi10.1109/ACEPT.2017.8168622en
dc.description.versionAccepted versionen
item.grantfulltextopen-
item.fulltextWith Fulltext-
Appears in Collections:EEE Conference Papers
Files in This Item:
File Description SizeFormat 
ACEPT_2017_Control of AFE Rectifier.pdf1.09 MBAdobe PDFThumbnail
View/Open

SCOPUSTM   
Citations 20

4
Updated on Aug 31, 2020

Page view(s) 50

309
Updated on Nov 24, 2020

Download(s) 50

100
Updated on Nov 24, 2020

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.