Please use this identifier to cite or link to this item:
https://hdl.handle.net/10356/87383
Title: | Non-heuristic automatic techniques for overcoming low signal-to-noise-ratio bias of localization microscopy and multiple signal classification algorithm | Authors: | Agarwal, Krishna Macháň, Radek Prasad, Dilip Kumar |
Keywords: | Localization Microscopy Multiple Signal Classification Algorithm |
Issue Date: | 2018 | Source: | Agarwal, K., Macháň, R., & Prasad, D. K. (2018). Non-heuristic automatic techniques for overcoming low signal-to-noise-ratio bias of localization microscopy and multiple signal classification algorithm. Scientific Reports, 8(1), 4988-. | Series/Report no.: | Scientific Reports | Abstract: | Localization microscopy and multiple signal classification algorithm use temporal stack of image frames of sparse emissions from fluorophores to provide super-resolution images. Localization microscopy localizes emissions in each image independently and later collates the localizations in all the frames, giving same weight to each frame irrespective of its signal-to-noise ratio. This results in a bias towards frames with low signal-to-noise ratio and causes cluttered background in the super-resolved image. User-defined heuristic computational filters are employed to remove a set of localizations in an attempt to overcome this bias. Multiple signal classification performs eigen-decomposition of the entire stack, irrespective of the relative signal-to-noise ratios of the frames, and uses a threshold to classify eigenimages into signal and null subspaces. This results in under-representation of frames with low signal-to-noise ratio in the signal space and over-representation in the null space. Thus, multiple signal classification algorithms is biased against frames with low signal-to-noise ratio resulting into suppression of the corresponding fluorophores. This paper presents techniques to automatically debias localization microscopy and multiple signal classification algorithm of these biases without compromising their resolution and without employing heuristics, user-defined criteria. The effect of debiasing is demonstrated through five datasets of invitro and fixed cell samples. | URI: | https://hdl.handle.net/10356/87383 http://hdl.handle.net/10220/45392 |
ISSN: | 2045-2322 | DOI: | 10.1038/s41598-018-23374-7 | Schools: | School of Computer Science and Engineering | Rights: | © 2018 The Author(s) (Nature Publishing Group). This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/ | Fulltext Permission: | open | Fulltext Availability: | With Fulltext |
Appears in Collections: | SCSE Journal Articles |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Non-heuristic automatic techniques for overcoming low signal-to-noise-ratio bias of localization microscopy and multiple signal classification algorithm.pdf | 6.02 MB | Adobe PDF | ![]() View/Open |
SCOPUSTM
Citations
50
3
Updated on Mar 5, 2025
Web of ScienceTM
Citations
50
3
Updated on Oct 24, 2023
Page view(s)
382
Updated on Mar 18, 2025
Download(s) 50
108
Updated on Mar 18, 2025
Google ScholarTM
Check
Altmetric
Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.