Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/87723
Title: Comparison of continuous and stop-and-go scanning techniques in photoacoustic tomography
Authors: Sharma, Arunima
Kalva, Sandeep Kumar
Pramanik, Manojit
Keywords: Continuous Scanning
Stop-and-go Scanning
Issue Date: 2018
Source: Sharma, A., Kalva, S. K., & Pramanik, M. (2018). Comparison of continuous and stop-and-go scanning techniques in photoacoustic tomography. Proceedings of SPIE - Photons Plus Ultrasound: Imaging and Sensing 2018, 10494, 104943L-.
Abstract: Photoacoustic tomography is an emerging imaging modality which has paved its way in preclinical and clinical trials owing to the multiple advantages it offers. A typical PAT system consists of a laser beam which homogeneously illuminates the sample giving rise to photoacoustic (PA) waves, which are collected using an ultrasound transducer (UST) rotating around the sample. Low cost, high sensitivity and easy availability have made single-element transducers (SETs) a preferred choice for acquiring these A-lines PA signal. Two methods have been reported for collection of these A-lines by SETs- (1) Stop-and-go scan and (2) Continuous scan. In stop-and-go scan, the stepper motor moves the SET to a predefined position where the SET collects multiple A-lines. Once the desired number of A-lines at that point have been collected and saved, the stepper motor moves to the next position and the process continues. A continuous scan is one in which the stepper motor rotates the SET continuously at a predefined speed. The A-lines are thus collected by a moving SET and are saved once the motor has stopped. In this work, we have compared the two types of scanning methods in terms of image quality, signal-to-noise ratio and time of scan by performing experiments on phantoms.
URI: https://hdl.handle.net/10356/87723
http://hdl.handle.net/10220/44475
DOI: 10.1117/12.2288095
Rights: © 2018 Society of Photo-optical Instrumentation Engineers (SPIE). This paper was published in Proceedings of SPIE - Photons Plus Ultrasound: Imaging and Sensing 2018 and is made available as an electronic reprint (preprint) with permission of SPIE. The published version is available at: [http://dx.doi.org/10.1117/12.2288095]. One print or electronic copy may be made for personal use only. Systematic or multiple reproduction, distribution to multiple locations via electronic or other means, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper is prohibited and is subject to penalties under law.
Fulltext Permission: open
Fulltext Availability: With Fulltext
Appears in Collections:SCBE Conference Papers

Files in This Item:
File Description SizeFormat 
Comparison of continuous and stop-and-go scanning techniques in photoacoustic tomography.pdf562.72 kBAdobe PDFThumbnail
View/Open

SCOPUSTM   
Citations 50

2
Updated on Mar 8, 2021

Page view(s)

253
Updated on Jun 24, 2021

Download(s) 50

57
Updated on Jun 24, 2021

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.