Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/88178
Full metadata record
DC FieldValueLanguage
dc.contributor.authorLam, Bhanen
dc.contributor.authorElliott, Stephenen
dc.contributor.authorCheer, Jordanen
dc.contributor.authorGan, Woon-Sengen
dc.date.accessioned2018-03-19T03:13:44Zen
dc.date.accessioned2019-12-06T16:57:48Z-
dc.date.available2018-03-19T03:13:44Zen
dc.date.available2019-12-06T16:57:48Z-
dc.date.copyright2018en
dc.date.issued2018en
dc.identifier.citationLam, B., Elliott, S., Cheer, J., & Gan, W.-S. (2018). Physical limits on the performance of active noise control through open windows. Applied Acoustics, 137, 9-17.en
dc.identifier.issn0003-682Xen
dc.identifier.urihttps://hdl.handle.net/10356/88178-
dc.description.abstractActive noise control through open windows is a noise mitigation technique that preserves natural ventilation in dwellings. Designing a practical open window active noise control system requires the knowledge of the physical limits on the attenuation performance. Of the numerous variables to be optimised, it is the control source configuration (quantity and position) that ultimately defines the maximum attenuation attainable by an active noise control system. The physical limits are characterised here by systematically investigating the performance of different physical arrangements of control sources, using a two-dimension simulation model based on the finite-element method, which includes the diffraction effects of the window. The simulations reveal that the best attenuation is achieved by placing the control sources away from the edges of the window. It also shows that the plane of control sources can be placed centrally with respect to the depth of the walls, for practical implementation with minimal performance degradation. The simulated attenuation as a function of frequency and window width, for different angles of noise incidence, can be used to provide an estimate of the number of control sources, based on the desired level of attenuation. This estimate helps to determine the configuration with the minimum number of control sources required for different scenarios, before a more detailed system design is undertaken.en
dc.description.sponsorshipNRF (Natl Research Foundation, S’pore)en
dc.format.extent28 p.en
dc.language.isoenen
dc.relation.ispartofseriesApplied Acousticsen
dc.rights© 2018 Elsevier. This is the author created version of a work that has been peer reviewed and accepted for publication by Applied Acoustics, Elsevier. It incorporates referee’s comments but changes resulting from the publishing process, such as copyediting, structural formatting, may not be reflected in this document. The published version is available at: [http://dx.doi.org/10.1016/j.apacoust.2018.02.024].en
dc.subjectActive Noise Controlen
dc.subjectFinite Element Methoden
dc.titlePhysical limits on the performance of active noise control through open windowsen
dc.typeJournal Articleen
dc.contributor.schoolSchool of Electrical and Electronic Engineeringen
dc.contributor.researchDigital Signal Processing Laben
dc.identifier.doi10.1016/j.apacoust.2018.02.024en
dc.description.versionAccepted versionen
dc.identifier.rims203641en
item.fulltextWith Fulltext-
item.grantfulltextopen-
Appears in Collections:EEE Journal Articles
Files in This Item:
File Description SizeFormat 
20180314_AcceptManuscript.pdf1.54 MBAdobe PDFThumbnail
View/Open

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.